4OM-1505-004_w.pdf - 第159页
4OM-1505 2-44 2. T roubleshooting on Each Section : Chap.2 0906-001 T4B41 Error ID Error Name, Description, Cause, and Remedy 1608000 Node Error Operation Node (1) Error 1609000 Node Error Relay Secquence Node (2) Error …

4OM-1505
2-43
2. Troubleshooting on Each Section : Chap.2
(16 Self-Diagnostics)
T4B40
Error ID Error Name, Description, Cause, and Remedy
1601000 Control Board
System error
1602000 Control Board
Control board error
(Cause 1) An error has occurred in the I/O communication.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1603000 Sensor
Paste detect sensor error
(Cause 1) The paste height detection sensor (B64) is not adjusted correctly.
(Remedy 1) Contact our service personnel for details.
1604000 System Error
Undened Error.
1605000 System Error
Illegal error code.
1606000 System Error
Internal data error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1)
Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1607000 System Error
Failed to caliculate position.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The amount of the recognition correction has exceeded the limited value
(10 mm twice).
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
(Remedy 2) Check the coordinates of the ducial mark and the value for printing
inaccuracy correction.
0906-001

4OM-1505
2-44
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B41
Error ID Error Name, Description, Cause, and Remedy
1608000 Node Error
Operation Node (1) Error
1609000 Node Error
Relay Secquence Node (2) Error
1610000 Node Error
Inp.&& Outp.Mac. Interface Node (3) Error
1611000 Node Error
PCB Transfer Node (4) Error
1612000 Node Error
PCB Chuck Node (5) Error
(Cause 1) Node failed in the communication with the host computer.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1613000 Node Error
Squeegee Head Node (6) Error
1614000
Node Error
PEC Recog. Node (7) Error
1615000 Node Error
Cleaning Unit Node (8) Error
1616000 Node Error
Blower Unit Node (9) Error
1617000 Node Error
Printing pressure control output node error
1618000 Node Error
Printing pressure control input node error
(Cause 1) Node failed in the communication with the host computer.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.

4OM-1505
2-45
2. Troubleshooting on Each Section : Chap.2
0906-001
T4B42
Error ID Error Name, Description, Cause, and Remedy
1619000 Node Error
Table Z axis motor controller node (17) error
1620000 Node Error
Table X axis motor controller node (19) error
1621000 Node Error
Table Theta axis motor controller node (21) error
1622000 Node Error
PCB Backup axis motor controller node (23) error
1623000 Node Error
Table Chute Width axis motor controller node (25) error
1624000 Node Error
Squeegee Driving axis motor controller node (27) error
1625000 Node Error
Stencil Y axis motor controller node (29) error
1626000 Node Error
Stencil Recog. X axis motor controller node (31) error
1627000 Node Error
PEC Recog. Y axis motor controller node (33) error
1628000 Node Error
PEC Recog. X axis motor controller node (35) error
1629000 Node Error
L Conveyor Width axis motor controller node (37) error
1630000 Node Error
R Conveyor Width axis motor controller node (39) error
(Cause 1) The motor controller node failed in the communication with the host computer
.
(Remedy 1) Shut down the power of the machine once and power up the machine again.
After that, restart the operation. When the same error still occurs, contact our
service personnel for details.
1631000 Pattern Program Data Error
Illegal pattern program.
(Cause 1) An illegal value is set in the pattern program data.
(Remedy 1) Press the [PRGM. CHECK] button in the "ERROR" window and check the
contents. After that, set the correct value.