4OM-1505-004_w.pdf - 第81页
4OM-1505 1-30 3. Maintenance Spots : Chap.1 Every 6 Months Lubrication Backup T able V ertical-Axis Guide Bushing (Three) Backup T able V ertical-Axis Ball Screw (Four) Every 6 Months Lubrication Backup T able V ertical-…

4OM-1505
1-29
3. Maintenance Spots : Chap.1
3.2.6 PCB Chuck Section
Upper Surface of PCB Transfer
Belt
Every Day Cleaning
PCB Positioning Side and
Upper Surface
Every Day Cleaning
Upper Surface Section of
Backup Table
Every Week Cleaning
Remove solder paste and dust
using a cloth soaked in industrial
alcohol. In the case that solder
paste can not be removed, scrape it
and clean it again using a cloth
soaked in industrial alcohol.
Remove solder paste and dust
using a cloth soaked in industrial
alcohol. In the case that solder
paste can not be removed, scrape it
and clean it again using a cloth
soaked in industrial alcohol.
Remove solder paste and dust
using a cloth soaked in industrial
alcohol. In the case that solder
paste can not be removed, scrape it
and clean it again using a cloth
soaked in industrial alcohol.
F4A18
0906-001

4OM-1505
1-30
3. Maintenance Spots : Chap.1
Every 6 Months Lubrication
Backup Table Vertical-Axis
Guide Bushing (Three)
Backup Table Vertical-Axis
Ball Screw (Four)
Every 6 Months Lubrication
Backup Table Vertical-Axis
Guide Bushing
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Note
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
F4A19
Linear Guide for PCB Clamping
Every Month Cleaning
Detach the cover and clean
the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Linear Guide for PCB Clamping
Every 5 years Lubrication
Detach the cover and apply grease
with a brush or a spatula.
Rear Side
Note
F4A20
0906-001

4OM-1505
1-31
3. Maintenance Spots : Chap.1
Linear Guide for Chute Width
Adjustment (Right Side)
Every 5 years Lubrication
Linear Guide for Chute Width
Adjustment (Left Side)
Every 5 years Lubrication
Linear Guide for Chute Width
Adjustment (Right Side)
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Linear Guide for Chute Width
Adjustment (Left Side)
Every Month Cleaning
Clean the stopper with an oiled rag.
Do not leave any waste
threads after cleaning.
Right Side
Left Side
Note
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
Torapezoid Screw for Chute Width
Change
(Left Side), (Right Side)
Every 6 Months Lubrication
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
(1)
(2)
Move up the backup table
Z axis.
Apply grease with a brush or
a spatula.
Note
F4A21
0906-001