Installation Preparatory Steps 68 Stationary Camera Type 25/33 Stationäre Kamera Typ 25/ 33 3.1 3 . 1 P r e p a r a t o r y S t e p s Preparatory Steps ► Move the component trolley at l ocation 1 out of the machine. Swit…

Installation
Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33 67
3
3 Installation
Installation
CAUTION - Do not hold or ca rry the cam era by its e lectronics unit.
CAUTION - Crash danger - Observe the installation height of the cameras
CAUTION
Do not hold or carry the camera by its electronics unit.
The camera electronics assembly is a sensitive unit and can be easily damaged.
► Only hold or carry the camera by its metal frame.
► Always pull the illumination unit carefully up and off.
► The metal housing must always be hooked out of the lower section of the camera.
CAUTION
Crash danger
When fitting the camera, make sure that you observe the correct installation height, otherwise
this could create a risk of head crash.

Installation
Preparatory Steps
68 Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33
3.1
3.1 Preparatory Steps
Preparatory Steps
► Move the component trolley at location 1 out of the machine.
Switch off the machine, disconnect it from the power supply and ...
► Switch off the machine, disconnect it from the power supply and secure it to prevent unauthorized
reactivation. Observe the instructions in section "1.2 Preparatory Work..." [ ➙ 56].
► If a stationary camera is already present, remove it.
For removing a stationary camera follow the installation instructions in reverse order.
Refer to the relevant installation chapter in this manual.
Used tape chute
► Loosen the two safety screws (1) on the used tape
chute and unhook the used tape chute.
► You may want to mark the position of the COT insert
to be able to install the COT insert at the same posi
-
tion later on.
► Remove the eight fastening screws (1) of the COT in
-
sert.
► Pull the COT insert out of the machine a bit for a bet
-
ter access to the installation position.

Installation
Converting the Reject Box
Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33 69
3.2
3.2 Converting the Reject Box
Converting the Reject Box
NOTICE
Before installing the camera
It is recommended to convert the reject box before installing the camera.
Dismantling NC 1
► Remove the four fixing screws (1) of the nozzle
changer (NC).
Dismantling NC 2
► Unplug the electrical (1) pneumatical connections (2)
of the nozzle changer and put the NC aside.
Dismantling the NC holder
► Remove the reject bin (1).
► Remove the fastening screws (3) of the right NC
holder (2) and lift off the NC holder.