00198142-01_AI_Stationary-Camera-25-33_TX_de_en.pdf - 第81页

Installation Completing the Mechanical Work Stationary Camera Typ e 25/33 Stationäre Kamera Typ 25/33 81 See also   4.2.1.1 Vision LED Contro ller VL C25 GigE DTC [03117587-xx] [ ➙ 8 7] 3.5 3 . 5 C o m p le t in g t h …

100%1 / 94
Installation
Fitting the Stationary Camera Type SST33
80 Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33
Inserting the Dust Cover
Putting on the Upper Part and Checking the Installation Height
NOTE: The upper section of the camera is assigned specifically to the lower section of the camera!
Inserting the Dust Cover
Insert the dust cover made of foam plastic (1) into the
bottom cover.
NOTICE
The upper section of the camera is assigned specifically to the lower section of the camera!
The upper section of the camera may not be used with a different bottom section. Both the up
-
per and lower sections are mechanically and electrically coordinated and may not be ex
-
changed for use with other cameras. The serial and version numbers of the top and bottom
sections of the camera must be identical.
Putting on the upper part
Put the upper part (1) on the basic unit.
Installation
Completing the Mechanical Work
Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33 81
See also
4.2.1.1 Vision LED Controller VLC25 GigE DTC [03117587-xx] [ ➙ 87]
3.5
3.5 Completing the Mechanical Work
Completing the Mechanical Work
Fasten the COT insert to its original position.
Check and correct the height of the NC holder (see "4.1.2.1 Setting the Nozzle Changer Height"
[➙84]).
Check and correct the height of the nozzle changer (see "4.1.2.2 Setting the Height of the Nozzle
Station" [ ➙ 85]).
Check the setting of the jumper on the NC (if one is present).
It must be set to 2-3 (see also "4.1.2.3 Jumpers on the Nozzle Changer" [ ➙ 86]).
Fit the NC and the nozzle station.
Install the used tape chute in location 1.
Move the component trolley into the machine.
Switch the machine on.
Check the function of the reject bin sensor and set the sensor, if required.
Make the settings in the software (see "3.6 Making the Settings in the Software" [ 82]).
Checking the installation height
Check the installation height.
When installed correctly, the upper part (1) is 2 mm
higher than the top edge of the conveyor rail (2).
CAUTION!
If the upper part protrudes too far, there is the danger of
a head crash.
Installation
Making the Settings in the Software
82 Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33
3.6
3.6 Making the Settings in the Software
Making the Settings in the Software
SST25: Saving the configuration
SST33: Saving the configuration
After start-up, the station software notifies you of the
changed hardware. Confirm the change as follows:
Switch over to the operator level Machine service.
Switch over to the service menu .
Go to the Machine Configuration view.
Check the setting of the PCB camera.
Confirm the changes with Save new configuration
and continue startup.
Calibrate the camera (see "4.1.1 Calibrating the
Heads and Cameras (SW70x)" [ 83]).
The installation is now complete.