00198142-01_AI_Stationary-Camera-25-33_TX_de_en.pdf - 第71页

Installation Converting the Reject Box Stationary Camera Typ e 25/33 Stationäre Kamera Typ 25/33 71 Fitting the r ear cover ► Fasten the rear cover (2) with three screw s (1) . The sensor cable is run through the opening…

100%1 / 94
Installation
Converting the Reject Box
70 Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33
Dismantling the sensor
Dismantle the sensor (1) on the right NC holder.
Dismantling the rear cover
Remove the three screws (1) fastening the rear
cover (2).
Move the cover a bit to the side and lift it off. Thus, it is
easier to thread the sensor cable.
Converting the sensor
Push the sensor through the opening (1) on the front
cover.
Installation
Converting the Reject Box
Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33 71
Fitting the rear cover
Fasten the rear cover (2) with three screws (1).
The sensor cable is run through the opening (3) in the
cover.
CAUTION!
Make sure not clamp any hoses or cables.
Fitting the reject bin holder
1. Nozzle station [03090348
-
xx]
The nozzle station is fitted after measuring the height.
2. Fastening screws of the nozzle station [00333782
-
xx]
3. Fastening screws for retaining bracket ISO10642-
M5x10-A2-70 [03082832
-
xx]
4. Fastening screws of the complete holder on the COT
insert DIN7984-M6x12-A2-70 [03081847
-
xx]
5. Fastening screws ISO 7380-2 M 3 x 6-A2-70
[03099571-xx], only for setting the sensor height
6. Three lugs for cable ties
7. Sensor [03088550
-
xx]
The sensor that is already installed and cabled on the
insert is used.
Fit the individual parts of the reject bin holder.
Use the cable ties to fix the sensor to the three lugs.
Fitting the reject bin holder
Fit the reject bin holder with two fastening screws
DIN7984-M6x12-A2-70 [03081847-xx] (1) on the
COT insert.
Push the sensor cable behind the cover as far as pos
-
sible.
CAUTION!
If too much cable length lies in front of the cover the reject
may damage the cable.
Installation
Converting the Reject Box
72 Stationary Camera Type 25/33 Stationäre Kamera Typ 25/33
Fitting the NC holder
Fit the right NC holder (1) with two fastening screws
DIN 7984-M6 x 12-A2-70 [03081847-xx] (2). Replace
the right NC holder by the supplied version without
nozzle station.
Do not fit the NC and the nozzle station yet!
Setting the sensor
1. Reject box
2. Sensor
3. Distance 2.0+/-1.0 mm
4. Fastening screws for setting the senor height
Insert the reject bin.
Set the sensor to a distance of 2.0+/-1.0 mm from the
reject bin.