PCP Series Manual Revision B / October 2021 Page 15 of 56 Disassemble the Pump 1. Place the pump on a clean work sur face. 2. Use a 2.5 mm hex key to remove the two M3 x 55 mm socket head cap scre ws from the rotor assem…

PCP Series Manual
Revision B / October 2021
Page 14 of 56
Disassemble and Clean the Pump
Remove the Pump from the Workcell
1. Remove the motor connection from the motor assembly of the pump.
2. Turn the luer lock dispense tip counterclockwise and pull to remove.
3. Discard the luer lock dispense tip.
4. Use a wrench to remove the material fitting from the fluid body.
5. Install a cap on the material fitting.
6. Use a 2.5 mm hex key to remove the bolt from the back of mount plate in the back
of the fluid body.
Figure 2: Remove Pump from Workcell
7. Remove the pump from the workcell.

PCP Series Manual
Revision B / October 2021
Page 15 of 56
Disassemble the Pump
1. Place the pump on a clean work surface.
2. Use a 2.5 mm hex key to remove the two M3 x 55 mm socket head cap screws from
the rotor assembly.
3. Separate the motor from the rotor assembly.
Figure 3: Separate Motor from Rotor Assembly
4. Remove the blue coupling from the rotor assembly.
Figure 4: Remove Coupling

PCP Series Manual
Revision B / October 2021
Page 16 of 56
5. Twist to unscrew the luer lock and remove it from the stator sleeve.
Figure 5: Remove Luer Lock
6. Twist to unscrew the union cap and remove it from the stator sleeve.
Figure 6: Remove Union Cap