OM-1754-001w_GS-F600.pdf - 第25页

Safe-19 Safety Precautions OM-1754 No. Alert Labels and Description (16) 10-0288- Before setting up the recycle conveyo r , open the feeder incorrect setu p preventive cove r . Description  When the recycle conveyor is …

100%1 / 190
Safe-18
Safety Precautions
OM-1754
No. Alert Labels and Description
(13)
10-0278-
Avoid dropping a cutter!
It is heavy and if dropped, an injury will result.
Remove or attach the cutter unit with the
handle securely held.
Description
Do not drop a cutter. Otherwise, a foot injury will result or the cutter itself may be
damaged.
Carefully handle each cutter one by one and do not drop any.
(14)
Description
Do not put any feeder sideways nor tools on the feeder bases. Otherwise, the
machine will break down.
(15)
10-0298-
kg
Description
Because the magazine is heavy, take care handling it when it is moved. Otherwise,
you might injure your arm or waist.
1303-001
5. Alert Labels
Safe-19
Safety Precautions
OM-1754
No. Alert Labels and Description
(16)
10-0288-
Before setting up the recycle conveyor,
open the feeder incorrect setup
preventive cover.
Description
When the recycle conveyor is to be used, set it with the feeder setup error
prevention cover opened.
(17)
10-0297-
Description
In the case that the total mass of the magazine exceeds 20kg, it should be lifted and
moved by two people.
1303-001
5. Alert Labels
Safe-20
Safety Precautions
OM-1754
6. Precautionary Items for Correct Operations
Requirements for Installation
Be sure to fulll the following requirements for safety purposes.
Overvoltage Category : Category
III
Pollution Degree : 2
Altitude : 1,000 m or less above the sea level
Overvoltage Categories refer to the level of Impulse Withstand Voltage
protection provided at the specied Pollution Degree.
Category III : Primary circuits of a device to which power is directly supplied from
the power distribution panel, and circuits from the distribution panel to
outlets.
Note
The term was changed from "Installation Category" to "Overvoltage
Category".
“Pollution Degree” is a degree of pollution severity.
Pollution Degree 2 : This equipment is used under the environment where
nonconductive pollution occurs, which may become
conductive temporarily due to occasional condensation.
Altitude means the height above sea level of the place where the machine is to
be used.
Note
When the machine is used in a place that has an altitude of 1,000 meters or
more, contact YAMAHA sales representatives.
1303-001