Notes: 1. Using P AM V ersion 3.0 1-6 CP-6 Series P AM Operation

100%1 / 69
Simplified Measurement Technique
The CP-6 series is designed so that the nozzle shafts are aligned in a straight line relative
to the head shafts. When a nozzle is changed, there is almost no variation between the
nozzle centers. This means that a PAM measurement can be performed for only 1 of the
6 nozzles, with the results for that nozzle applying to the other nozzles. The accuracy
can therefore be checked simply by repeating the nozzle center measurement.
1. Use the standard 3216R part data as the measurement part data.
2. Assuming that the following nozzle combination is used, a 1.3mm nozzle is
mounted at No.3.
No.1 nozzle 0.7mm
No.2 nozzle 1.0mm
No.3 nozzle 1.3mm
No.4 nozzle *.*mm
No.5 nozzle *.*mm
No.6 nozzle *.*mm
3. Create the Nozzle Assignment Table as shown below.
• Nozzle Assignment Table
Nozzle_No Nozzle_Size Back_light_size Bend_Limit Nozzle_type
1 0.0 00 0.000 0
2 0.0 00 0.000 0
3 1.3 12 0.050 0
4 0.0 00 0.000 0
5 0.0 00 0.000 0
6 0.0 00 0.000 0
4. Copy the No.3 measurement results to all the other nozzles.
5. Perform a nozzle center measurement.
6. Run PAM again to verify that an accuracy result is obtained.
1. Using PAM
Version 3.0 1-5 CP-6 Series PAM Operation
Notes:
1. Using PAM
Version 3.0 1-6 CP-6 Series PAM Operation
2. Boot-up in PAM Mode
Insert the PAM software ROM card and reset start the machine. The machine will boot
up in the PAM mode. Transmit the Proper data, status data, and the programs once the
machine reboots. Reboot the machine after transmitting the data.
The display shown above is the first screen in the PAM mode. "PAM Mode"
displays on the screen if the machine boots up in the PAM mode.
The Proper data measurements for the machine and the Mark camera (excluding
those for station 11) must be complete prior to using the PAM software.
2. Boot-up in PAM Mode
Version 3.0 2-1 CP-6 Series PAM Operation