CP6S-PAM操作手册.pdf - 第44页

The nozzle data selected on command page 140 displays here. Function Key Menu Monitor Display Second Display Area : READY First Status Area : "No.1 NOZZLE", "No.2 NOZZLE", "No.3 NOZZLE" &quo…

100%1 / 69
Function Key Operation
All deg.: Displays the placement/measurement sequence data at all angles for the
nozzle type selected on command page 140 To page 141-1
0 deg.: Displays the placement/measurement sequence data for placement at 0
degrees for the nozzle type selected on command page 140 To page 141-2
90 deg.: Displays the placement/measurement sequence data for placement at 90
degrees for the nozzle type selected on command page 140 To page 141-3
180 deg.: Displays the placement/measurement sequence data for placement at 180
degrees for the nozzle type selected on command page 140 To page 141-4
270 deg.: Displays the placement/measurement sequence data for placement at 270
degrees for the nozzle type selected on command page 140 To page 141-5
RETURN: Returns to page 140 To page 140
6. Description of Commands
Version 3.0 6-11 CP-6 Series PAM Operation
The nozzle data selected on command page 140 displays here.
Function Key Menu
Monitor Display
Second Display Area
: READY
First Status Area : "No.1 NOZZLE", "No.2 NOZZLE", "No.3 NOZZLE"
"No.4 NOZZLE", "No.5 NOZZLE", "No.6 NOZZLE"
Function Key Operation
Deviation: Displays the nozzle deviation for each axis (X, Y and Q)
To page 141-1-1
Deviat’n avg.: Displays the nozzle deviation average for each head and specified
axis (X, Y or Q) To page 141-1-2
Max/Min dev.: Displays the max/min nozzle deviation amount for each head and
specified axis (X, Y or Q) To page 141-1-3
Accuracy: Displays the nozzle accuracy (3s) for each head and specified axis
(X, Y or Q) To page 141-1-4
RETURN: Returns to page 141 To page 141-1
Page141
CP_6.PROGRAM
000000000000
000000000000
Prod 00000 Sche 00000
P1.00 off line
Operation : Front
Ready
RETURN
jog
XY
C
Deviat'n avg.
Avg.dX
- 13
Max.dX
26
Max.dX
- 13
3sig.X
18
Avg.dQ
- 278
Max.dQ
476
Max.dQ
- 278
3sig.Q
483
- 9
Avg.dY
19
Max.dY
- 9
Max.dY
4
3sig.Y
No.1 NOZZLE
Measurement Result
Nozzle Type
All Nozzle
All degrees
All data
5000
dXdY
[1/1000mm]
dQ
[1/1000deg]
Max/Min dev. AccuracyDeviation
C6PM6023
Deviation Deviat'n avg. Max/Min dev. Accuracy RETURN
Specific Nozzle Data Display
No.1 ~ No.6 NOZZLE
Page
141-1
6. Description of Commands
Version 3.0 6-12 CP-6 Series PAM Operation
Pressing [All deg.] displays the deviation for the X, Y and Q-axes for all sequences placed
with the nozzle type selected on command page 141.
When [0 deg.], [90 deg.], [180 deg.], or [270 deg.] is selected, the deviation for the X, Y
and Q-axes for all sequences placed with the selected nozzle types and placement angles
are displayed.
Function Key Menu
Monitor Display
The selected nozzle data displays under the heading "Nozzle Type" at the upper
right of the first display area.
The selected angle data is displayed under the heading "Nozzle Type".
The units of measurement in the display are 1/1000 mm for dX and dY; and
1/1000° for dQ.
The data used to calculate the deviation amount displays in the middle right of the
1st display area.
"****" displays as an error message if a vision processing error occurs while the
software reads the placement data.
Inputting a sequence number from the numerical keypad jumps the display to that
particular sequence.
Page141
CP_6.PROGRAM
000000000000
000000000000
Prod 00000 Sche 00000
P1.00 off line
Operation : Front
Ready
RETURN
jog
XY
C
-PAGE Data Save
Seq.
3
4
5
6
7
8
9
10
11
12
dX
DEVIATION
Deviations for each measuring point
Nozzle Type
No. 1
All degrees
All data
5000
dXdY
[1/1000 mm]
dQ
[1/1000 deg]
+PAGE
- 10
18
- 9
- 26
****
10
5
0
- 1
- 4
dY
- 1
3
4
- 7
****
- 1
2
5
- 3
- 6
dQ
90
- 320
100
489
****
- 789
545
798
- 743
754
C6PM6026
+PAGE -PAGE Data Save RETURN
Specific Nozzle Deviation Display
Deviation
Page
141-1-1
6. Description of Commands
Version 3.0 6-13 CP-6 Series PAM Operation