CP6S-PAM操作手册.pdf - 第46页

Second Display Area : READY First Status Area : DEVIATION Function Key Operation + PAGE: Displays the next page - PAGE: Displays the previous page Data Save: Prints the deviation information for the angle specified on pa…

100%1 / 69
Pressing [All deg.] displays the deviation for the X, Y and Q-axes for all sequences placed
with the nozzle type selected on command page 141.
When [0 deg.], [90 deg.], [180 deg.], or [270 deg.] is selected, the deviation for the X, Y
and Q-axes for all sequences placed with the selected nozzle types and placement angles
are displayed.
Function Key Menu
Monitor Display
The selected nozzle data displays under the heading "Nozzle Type" at the upper
right of the first display area.
The selected angle data is displayed under the heading "Nozzle Type".
The units of measurement in the display are 1/1000 mm for dX and dY; and
1/1000° for dQ.
The data used to calculate the deviation amount displays in the middle right of the
1st display area.
"****" displays as an error message if a vision processing error occurs while the
software reads the placement data.
Inputting a sequence number from the numerical keypad jumps the display to that
particular sequence.
Page141
CP_6.PROGRAM
000000000000
000000000000
Prod 00000 Sche 00000
P1.00 off line
Operation : Front
Ready
RETURN
jog
XY
C
-PAGE Data Save
Seq.
3
4
5
6
7
8
9
10
11
12
dX
DEVIATION
Deviations for each measuring point
Nozzle Type
No. 1
All degrees
All data
5000
dXdY
[1/1000 mm]
dQ
[1/1000 deg]
+PAGE
- 10
18
- 9
- 26
****
10
5
0
- 1
- 4
dY
- 1
3
4
- 7
****
- 1
2
5
- 3
- 6
dQ
90
- 320
100
489
****
- 789
545
798
- 743
754
C6PM6026
+PAGE -PAGE Data Save RETURN
Specific Nozzle Deviation Display
Deviation
Page
141-1-1
6. Description of Commands
Version 3.0 6-13 CP-6 Series PAM Operation
Second Display Area : READY
First Status Area : DEVIATION
Function Key Operation
+ PAGE: Displays the next page
- PAGE: Displays the previous page
Data Save: Prints the deviation information for the angle specified on page 141.
All the sequences placed with the selected nozzle size are sent to the
printer if [All deg.] is selected.
Selecting [0 deg], [90 deg.], [180 deg.] or [270 deg.] sends the deviation
values for the sequences placed with the selected nozzle size at the
specified angle to the printer.
The printed format is shown on the following page.
RETURN: Returns to page 141-1 To page 141-1
Print Format
The angle data displayed between "Nozzle Type" and "Data No." is what is sent to the
printer.
Deviation Nozzle type 1
All deg.
X, Y [1/1000 mm] Q [1/1000 deg]
dX, dY [1/1000 mm] dQ [1/1000 deg]
N3 X -10000 Y 10000 Q 9000 dX -10 dY -1 dQ 90
N4 X -10000 Y 10000 Q 9000 dX 18 dY 3 dQ -320
Note: "****" displays for the sequence data if a vision processing error occurs while the software
reads the placement data (dX, dY, dQ).
6. Description of Commands
Version 3.0 6-14 CP-6 Series PAM Operation
This function displays the deviation average for the X, Y and Q-axes for all heads (A~T).
The X, Y, and Q-axis deviation averages for all of the sequences placed with the nozzle
type specified on command page 141 will display after selecting "All deg.".
The X, Y and Q-axis deviation averages for all sequences placed with the selected nozzle
types and placement angles are displayed when [0 deg.], [90 deg.], [180 deg.], or [270
deg.] are selected.
If a vision processing error occurs while reading placement coordinates, that sequence
data cannot be used for the calculations.
A "0" displays for the placing positions not yet calculated.
Function Key Menu
Monitor Display
Second Display Area
: READY
First Status Area : DEV. AVG.
Page141
CP_6.PROGRAM
000000000000
000000000000
Prod 00000 Sche 00000
P1.00 off line
ST 1N
ST 2N
ST 3N
ST 6N
ST 7N
ST 8N
ST10N
ST11N
3D 5Er****
3D 5Er****
3D 5Er****
3D 5Er****
3D 5Er 0
3D 5Er 0
3D 5Er 0
3D 5Er 0
Operation : Front
RETURN
Ready
jog
XY
C
Head
STATUS
P Mode
Recovery
T Mode
PAM Mode
Product
E Pass
Joint
DEV. AVG.
Axis
C6PM6029
Axis RETURNHead
Specific Nozzle Deviation Average
Deviat'n avg.
Page
141-1-2
6. Description of Commands
Version 3.0 6-15 CP-6 Series PAM Operation