4OM-1050-002.pdf - 第133页
Check Code Display Section A Display Section B 801701 T each Nozzle Nozzle Down Error .(L) Bypass 801702 T each Nozzle Nozzle Down Error .(H) Bypass 801703 T each Nozzle Recognition T each Error . Bypass 801704 T each No…

0207-004 2-17 AFO01ETRP
Check Code Display Section A Display Section B
801201 Stat Auto Head Cpu Communication error occurred.(CPU2-CPU3)
Recovery
801202 Stat Auto Head Head cam origin return action not complete.(Not CAM ORIGIN po-
Recovery sition)
801203 Stat Auto Head Head Driver communication is time out.(from cpu3 job)
Recovery
801204 Stat Auto Head Nozzle change action not complete.(cam lock action NG)
Recovery
801205 Stat Auto Head Head cam position return action not complete.
Recovery
801206 Stat Auto Head Nozzle change action not complete.(cam free action NG)
Recovery
801207 Stat Auto Head Nozzle change action not complete.(Not CAM ORIGIN position)
Recovery
801208 Stat Auto Head Unselected Nozzle Drop.
Recovery
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
801301 Pickup Position Feedback value out of range. Please check feeder.
Feedback
801401 Pickup Level Data Calculated data out of range. Please check library data and offset
data.
801402 Placement Level Calculated data out of range. Please check library data and offset
Data data.
801501 Feeder Index
Position
801502 Feeder Index
Position
801601 Product Restart Restart production with semi-auto(after specified step) mode.
801602 Product Restart Restart production with warm start mode.
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
1.3 Machine lnformation

Check Code Display Section A Display Section B
801701 Teach Nozzle Nozzle Down Error.(L)
Bypass
801702 Teach Nozzle Nozzle Down Error.(H)
Bypass
801703 Teach Nozzle Recognition Teach Error.
Bypass
801704 Teach Nozzle Teach Error Data.
Bypass
801705 Teach Nozzle Lighting Check.
Bypass
801706 Teach Nozzle Nozzle Level.
Bypass
801707 Teach Nozzle Nozzle Drop
Bypass
801708 Teach Nozzle Dummy Nozzle.
Bypass
801709 Teach Nozzle Manual Bypass.
Bypass
80170a Teach Nozzle Nozzle Change Error.(Cam lock action)
Bypass
80170b Teach Nozzle Nozzle Change Error.(Cam Free action)
Bypass
80170c Teach Nozzle Cam Origin Error.
Bypass
(Contents) The nozzle to be taught was bypassed.
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
801801 Teach Head Bypass Communication Error.
801802 Teach Head Bypass Head Origin.
801803 Teach Head Bypass Overtime Head Origin Return.
(Contents) The nozzle to be taught was bypassed.
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
0110-003 2-1 8 AFO01ETRP
1.3 Machine lnformation

Check Code Display Section A Display Section B
801804 Teach Head Bypass Unselected Nozzle Drop.
801805 Teach Head Bypass Dummy Nozzle.
801806 Teach Head Bypass Manual Bypass.
801807 Teach Head Bypass Alarm Error.
(Contents) The nozzle to be taught was bypassed.
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
801901 Nozzle Adjustment Nozzle UP&Down Action is not Available.
801902 Nozzle Adjustment Communication error.
(Contents) Self-Diagnostics Error Message
(Description) Follow the described instructions to reset the machine to its normal con-
dition.
When the machine cannot be set to its normal condition, consult our
service personnel for the remedy.
801a01 Warning Operation Product started by RUN MODE "PASS" Operation.
801a02 Warning Operation The P.C.B. before component placing was conveyed from X/Y table.
801a03 Warning Operation The P.C.B. in the middle of component placing was conveyed from
X/Y table.
801b01 Lightning Surge Lightning Surge Protector works; Q204.
Warning
801b02 Lightning Surge Lightning Surge Protector works; Q204. Running continue.
Warning
801c01 Information This placement step was detected outside of the possible range.
This step is auto skip running.
801d01 Semi-auto (continue) Production operation was interrupted for the state where PCB be-
start mode auto fore component are placed exists on XY table.
change
801e01 Placement Level Calculated data out of range. Please check library data and pattern
Data program data.
801f01 Warm start mode Operation was canceled for the state where the P.C.B. in the middle
auto change of component placing is on X/Y table.
(Contents) Self-Diagnostics Error Message
(Description) Confirm the displayed contents.
0207-004 2-19 AFO01ETRP
1.3 Machine lnformation