1.4 Maintenance Method 0307-005 1-76 AFO01ETRP (23) Wipe off excess grease from the linear guide section with an oiled rag. It is also required to clean the linear scale encoder heads. Refer to "1.4.9 Cleaning of Li…

1.4 Maintenance Method
0307-005 1-75 AFO01ETRP
(20) Press the [Next] button. The following sheet appears.
Fig. 4A84-14
(21) Press the [ALL] button entitled "ZERO" to zero all devices.
Press one of the [F1], [F2A], [F3B], [F2B], [F3A] and [F4] buttons
entitled "FEEDER READY" to set the machine ready for operation.
(22) Press the [ON] button entitled "MOVE". In 2 seconds, press the
[ENABLE] button on the operation panel. The F2 linear guide moves
to the cleaning position.
Fig. 4A84-15

1.4 Maintenance Method
0307-005 1-76 AFO01ETRP
(23) Wipe off excess grease from the linear guide section with an oiled
rag.
It is also required to clean the linear scale encoder heads.
Refer to "1.4.9 Cleaning of Linear Scale Sections" for details.
(24) Clean the linear guides (12 places) in the same way.
Whenever you notice that you forgot to clean any of the linear
guides, press the [Back] button. In 2 seconds, press the
[ENABLE] button on the operation panel. The previous clean-
ing position is selected.
Press the [End] button to terminate the operation.
Press the [ALL] button entitled "ZERO". In 2 seconds, press the
[ENABLE] button on the operation panel to zero all device.
(25) After the lubrication is completed, be sure to attach the lubrication
covers to the front and rear sides of the machine.
(26) Confirm whether the reference mark on the linear scale can be
detected or not.
(26-1) When the [Ref Mark Detect] tab is pressed in the "Fdr.
Crg." tab sheet, the following tab sheet appears.
Fig. 4A84-16 "Ref Mark Detect" Tab Sheet

1.4 Maintenance Method
(26-2) When the [Start Reference Mark Detection] button is
pressed in the "Ref Mark Detect" tab sheet, the following
sheet appears.
Fig. 4A84-17
(26-3) Press the [ON] button entitled "MOVE". In 2 seconds,
press the [ENABLE] button on the operation panel.
Feeder Carriages #3 and #4 move to the F1 side and the
following sheet appears.
Fig. 4A84-18
(26-4) Press the [Next] button.
When the [ENABLE] button on the operation panel is
pressed in 2 seconds after the [ON] button (entitled
"MOVE"), "2. Move F4 Axis to Ref Mark (-)" is executed.
Follow the same procedure repeatedly and confirm that
the reference marks (Procedure of Operation: 3 through
9) are detected.
0307-002 1-77
AFO01ETRP