0210-004 2 - 1 5 4 AFO01ETRP Error ID ltem Description 660206 Nozzle Skip Nozzle Level (Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the master nozzle in the offset data. (Remedy 1…

0110-003 2-153 AFO01ETRP
Error ID ltem Description
660101 Nozzle Recog. Recognition Error Code
Note: Refer to “4.3.4 Nozzle Recognition Errors” for the detailed error display.
660201 Nozzle Skip Nozzle Down Error (L)
660202 Nozzle Skip Nozzle Down Error (H)
660203 Nozzle Skip Recognition Teach Error
(Cause 1) When the selected nozzle reached the L or H level during operation, the optical
beam of the sensor was shielded (not received).
The sensor may be defective.
(Remedy 1) Remove the dirt on the nozzle end and insert the nozzle deep inside.
The sensor may be defective. If necessary, replace the sensor with a new one.
Before replacing the sensor, contact our service personnel for some advice.
660204 Nozzle Skip Teach Error Data
(Cause 1) Dirt and dust adhere to the nozzle and an error is found in the nozzle teaching
operation.
(Remedy 1) Remove dirt and dust from the nozzle end and re-perform the nozzle teaching
operation.
660205 Nozzle Skip Lighting Check
(Cause 1) The diffusion plate of the nozzle may be dusty and dirty or scratched.
(Remedy 1) Clean the diffusion plate or replace it with a new one.
3.3 Error IDs and Remedial Procedures

0210-004 2-154 AFO01ETRP
Error ID ltem Description
660206 Nozzle Skip Nozzle Level
(Cause 1) This error occurs when the L value exceeds the tolerance in comparison with the
master nozzle in the offset data.
(Remedy 1) Check if a big value is set as an L level of the master nozzle in the offset data.
Check if the nozzle is broken or dirt adheres to the end.
660207 Nozzle Skip Nozzle Drop
(Cause 1) When a “NOZ. DOWN ERR (L)” error occurs, the nozzle is bypassed and the nozzle
bypass data indicates that “BYPASSED” appears as a low nozzle item.
(Remedy 1) Open the “Head/Noz. Bypass” tab sheet in the “OPN. MODE” window (submenu)
and press the [Reset Noz. Bypass] button. The “Bypass” in the “Nozzle Height”
text box disappears, indicating that “Bypass” is canceled.
660208 Nozzle Skip Dummy Nozzle
660209 Nozzle Skip Manual Bypass
(Cause 1) This appears when some nozzles are bypassed manually.
(Remedy 1) When the [Reset Noz. Bypass] button is pressed in the “Head/Noz. Bypass” tab
sheet of the “OPN. MODE” window (submenu), the manual bypass designation
of all nozzles is all canceled.
66020a Nozzle Skip Nozzle Change Error.(Cam lock action)
66020b Nozzle Skip Nozzle Change Error.(Cam Free action)
66020c Nozzle Skip Cam Origin Error.
66020d Nozzle Skip Nozzle Teach Error.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
3.3 Error IDs and Remedial Procedures

0110-003 2-155 AFO01ETRP
Error ID ltem Description
660301 Head Skip Communication Error
660302 Head Skip Head Origin
660303 Head Skip Overtime Head Origin Return
660304 Head Skip Unselected Nozzle Drop
660305 Head Skip Dummy Nozzle
660306 Head Skip Manual Bypass
660307 Head Skip Alarm Error.
(Cause 1) Self-Diagnostics Error Message
(Cause 2) The voltage of the stabilization power supply unit (PSU) is abnormal.
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
(Remedy 2) Consult our service personnel for details.
660401 Nozzle Level Nozzle Level (Low) Was More Than Tolerance.
660402 Nozzle Level Nozzle Level (Low) Was Less Than Tolerance.
660403 Nozzle Level Nozzle Level (High) Was More Than Tolerance.
660404 Nozzle Level Nozzle Level (High) Was Less Than Tolerance.
(Cause 1) This error occurs when there is a big difference in nozzle levels in comparison with
the master nozzle during teaching operation.
(Remedy 1) Re-teach the data of the master nozzle.
660501 Master Head Offset Linear Measure System Was At High Position.
660502 Master Head Offset Linear Measure System Was At Low Position.
(Cause 1) The master nozzle or the linear measure detection sensor may not be attached
correctly.
(Remedy 1) Attach the master nozzle correctly.
It is required to adjust the linear measure detection sensor after it is attached
correctly.
3.3 Error IDs and Remedial Procedures