4OM-1050-002.pdf - 第218页

Error ID Item Description 400305 Load Power Circuit The fdr .crg. axis safety guard (a) is open. 400306 Load Power Circuit The fdr .crg. axis safety guard (b) is open. (Cause 1) The feeder work area safety door was opene…

100%1 / 345
Error ID Item Description
400301 Load Power Circuit The [emergency stop] switch was pressed.
Refer to “2.3 [EMERGENCY STOP] Switch Pressed” for “(Cause 1)” and “(Remedy 1)”.
400302 Load Power Circuit The air pressure is too low.
(Cause 1) The main air pressure has dropped below the specified one.
.
Fig. 4B16
(Remedy 1) Adjust the pressure to the correct one.
Turn Knob (1) to adjust the main air pressure to the specified one (0.45 MPa (4.6
kgf/cm
2
)).
400303 Load Power Circuit Circuit porotector is active.
(Cause 1) The circuit breaker in the machine was activated.
(Remedy 1) Consult our service personnel for details.
400304 Load Power Circuit The machine’s front safety door is open.
(Cause 1) The front safety door was opened.
(Remedy 1) Close the front safety door after pressing the [RETURN] button and zero all axes.
Then, re-start the operation.
0301-005 2-100 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
400305 Load Power Circuit The fdr.crg. axis safety guard (a) is open.
400306 Load Power Circuit The fdr.crg. axis safety guard (b) is open.
(Cause 1) The feeder work area safety door was opened.
(Remedy 1) Close the feeder work area safety door after pressing the [RETURN] button and
zero all axes. Then, re-start the operation.
400307 Load Power Circuit Load power-on timeout.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
400401 Load Control Power Circuit
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
400501 Lightning Surge Warning Lightning Surge Protector works; Q204. Load power on with
reset operation.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Zero all axes and re-start the operation.
When the machine cannot be set to its normal condition, consult our service
personnel for the remedy.
410101 PLACEMENT NOZZLE APPROPRIATE NOZZLE MISSING.
(Cause 1) A nozzle different from the nozzle-related data is attached.
(Remedy 1) Check the attached nozzle and the “Nozzle Data” window (described in “4. Nozzle
Data” in “Section 5 (Vol. 3: Programming and Machine Data)” and reset the ma-
chine to its normal condition.
410201 Alternate Mode Available fdr.carriage is not found.
(Cause 1) A wrong parameter is set in the “Alternate” tab sheet.
(Remedy 1) Check the carriage to be used and correct the wrong parameter if any.
0210-004 2-101 AFO01ETRP
3.3 Error IDs and Remedial Procedures
Error ID Item Description
410301 Current Pattern Program
No Exist
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Perform a program change operation.
When the program change operation cannot be performed, contact our service
personnel.
410401 Component Cannot refer to component data.
(Cause 1) A mistake is found in the placement feeder location data of the pattern program data.
(Remedy 1) Check the placement feeder location data. If necessary, correct the mistake.
410501 Placement Data Already placed
410502 Placement Data Placement step missing. Start and recovery with WARM
START.
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Follow the described instructions and reset the machine to its normal condition.
410601 Component Data Available nozzle is not found.
410701 Nozzle Type
(Cause 1) A correct nozzle may not be attached or the attached nozzle may not conform to the
placement head/nozzle data and the nozzle type data.
(Remedy 1) Check the nozzle attached to the head of the machine.
Refer to the “4. Nozzle Data” in “Section 5 (Vol. 3: Programming and Machine
Data)” and check the placement head/nozzle data and the nozzle type data.
410801 Current Pattern Program
No Exist
(Cause 1) Self-Diagnostics Error Message
(Remedy 1) Perform a program change operation.
When the program change operation cannot be performed, contact our service
personnel.
410901 PEC Inspect Data Overflow P.E.C. inspect data count.
(Cause 1) The pattern program data is wrong.
(Remedy 1) Create a correct pattern program.
0207-004 2-102 AFO01ETRP
3.3 Error IDs and Remedial Procedures