4OM-1050-002.pdf - 第41页

Fig. 4A28-1 Front View of Machine 1.3 Maintenance Spots 0307-001 1-27-1 AFO01ETRP

100%1 / 345
(13) Feeder Carriage Section
1.3 Maintenance Spots
0307-005 1-27 AFO01ETRP
Fig. 4A28 Top View of Machine
Linear Guide Rails 1M13
Every Month Cleaning
Clean the carriage with an oiled rag.
Yoke Sides of Linear Motors 1M13-1
Every Month Checking/Cleaning
Check for components and/or foreign substances
adhered to the yoke sides of the linear motors. If neces-
sary, clean the yoke sides with a rag.
Refer to "1.4.10 Cleaning of Linear Motor's Yoke Sides"
for details.
Do not bring any metal of high magnetizability close
to this. Otherwise, such metal will easily be magne-
tized and attracted, causing an injury to the operator
and/or a mechanical breakdown.
Do not bring any magnetizable material close to this.
Those who wear implanted pacemakers should not
work inside the machine. Otherwise, the pacemaker
may be affected by magnetism, leading to a serious
accident.
CAUTION
WARNING
Fig. 4A28-1 Front View of Machine
1.3 Maintenance Spots
0307-001 1-27-1 AFO01ETRP
Grease Nipples
Magnified View of Feeder Carriage
Slide Block of Linear Guide
Linear Scale in Feeder Carriage Section
(Located in the areas of F1 through F4)
Encoder Head
Slide Block of Linear Guide (Front Side) 6M4
Every 6 Months Lubrication (DAPHNE EPONEX GREASE No. 1)
Grease should be applied every 6 months after the initial month.
* Use the FL- and P-type or the U- and P-type attachments.
Refer to "1.4.8 Lubrication of Linear Guide in Feeder Carriage Section" for details.
P Type
FL Type U Type
Fig. 4A29 Front View of Machine
0307-005 1-28
AFO01ETRP
1.3 Maintenance Spots