4.5 Menu Structure
4.5.1 “Main Menu“ Menu Structure
t Navigating the menus (see Chapter 4.4, page 16).
Level 1: Level 2: Description
SETUP BALANCE Set the functions of the device.
GEN.SERV.
“General services”
Reset the menu to factory settings.
DEVICE RS-232
“RS232, 9-pin”
Define the parameters for the COM interface.
USB
“USB-C”
Define the parameters for the USB interface.
EXTRAS Define the functions of the operating display.
DATA.OUTP.
“Data output”
COM.SBI
“SBI communication”
Configure the automatic data output.
PRNT.PR.
“Printout settings”
Perform the settings for the printout.
APPLIC.
Applications”
WEIGH Determine the weight value of a sample.
Activate the functions for all applications.
COUNT Determine the number of parts that have approximately equal weight.
PERCENT
“Percent weighing”
Determine the percentage share of a
sample based on a reference weight.
NET.TOT.
“Net total”
Carry out the weighing of components for a mixture.
TOTAL
“Totalizing”
Add weight values of independent weighing processes in a memory.
ANIMALW.
Animal weighing”
Weigh unstable samples, e.g., animals. This program calculates the av-
erage of several measurement cycles.
CALC.
“Calculation”
Calculate the weight value using a multiplier or divisor, e.g., for deter-
mining the weight per unit area of paper.
DENSITY
“Density determination”
Determine the density of solid samples based on the buoyancy meth-
od.
STATIST.
“Statistics”
Save and statistically analyze weight values and calculated values.
18 BSA II Operating Instructions
Operating Design
Level 1: Level 2: Description
INPUT DEV.ID. Save the entered ID number for the device.
DATE Set the date.
TIME Set the time.
SERV. PW. Activate the service mode.
INTERV. The SBI output rate can be set from 0 - 9999 seconds.
INFO
“Device infor-
mation”
VERSION
“Version number”
Display the software version number.
SER. NO.
“Serial number”
Display the device’s serial number.
MODEL Display the device’s model designation.
BAC VER. Display the version of the BAC processor.
LANGUAG. Set the menu language of the operating display.
4.5.2 “Toggle Between Weight Units“ Menu Structure
t Navigating the menus (see Chapter 4.4, page 16).
Level 1: Description
Unit 1 – unit 4 Define the displayed weight unit and the resolution for the 1st to 4th convertible unit.
BSA II Operating Instructions 19
Operating Design
4.6 Parameter List
4.6.1 “SETUP“/“BALANCE“ Menu
Parameters Settings Explanation
AMBIENT V.STABLE Sets the ambient conditions to “very stable”: Activates a fast change in the
weight values in the event of a load change with a high output rate.
Recommended for the following work environment:
Very stable table near the wall
Closed and calm room
STABLE* Sets the ambient conditions to “stable”. Recommended for the following
work environment:
Stable table
Slight movement in the room
Slight draft
UNSTABL. Sets the ambient conditions to “unstable”: Activates the delayed change in
weight values with a reduced output rate. Recommended for the following
work environment:
Simple office desk
Room with moving machinery or personnel
Slight air movement
V.UNSTBL. Sets the ambient conditions to “very unstable”: Activates a significantly
delayed change in the weight values and long wait for stability with a further
reduction in the output rate.
Recommended for the following work environment:
Noticeable and slow floor vibrations
Noticeable building vibrations
Weighed goods moved
Very strong air movements
APP.FILT. FINAL.RD.* Activates a filter that enables a fast change in the display for very fast load
changes. Display changes with minimal load changes (in the digit range) oc-
cur more slowly.
FILLING Activates a filter that enables a very fast change in the display with minimal
load changes, e.g., when dosing or filling vessels.
STB.RNG. V. ACC. Sets the stability to “very accurate“.
ACC.* Sets the stability to “accurate“.
FAST Sets the stability to “fast“.
V. FAST Sets the stability to “very fast“.
AUTOZER. ON* Activates automatic zeroing. The display is automatically set to zero in case
of a deviation of 0 less than (X).
OFF Deactivates automatic zeroing. Zeroing must be triggered with the [Zero]
button.