Alarm trace mode
1. To change to Alarm trace mode, push the Mode Key several times until [AL] is
displayed.
2. The display automatically changes to the page selection display screen shown
below.
3. The page to be monitored is selected by advancing with the [Up Key] and
returning with the [Down Key]. The 2 digits in the display are the alarm code. In
the figure below, the third previous error code was [61].
4. The most recent 7 alarm codes, the CPU version, and the alarm trace all clear
screen are displayed in the following order.
5. Push the [Mode Key] to return to the page selection display screen, and push it a
second time to advance to the next mode.
XP1MA013E
Current alarmn
Name
Select
Page
Name
Select
Page
1 alarm previous1
2 alarms previous2
3 alarms previous3
4 alarms previous4
5 alarms previous5
6 alarms previous6
7 alarms previous7
CPU Version
Alarm trace "All clear"
XP1MA012E
XP1MA011E
XP1MA010E
Part 4 Chapter 1 Servo Amplifier Adjustments
Edition 3.0 4-1-4 XP-142E Mechanical Reference
Basic mode
1. To change to Basic mode, push the Mode Key several times until [bA] is displayed.
2. The display automatically changes to the page selection display screen shown
below.
3. The page to be monitored is selected by advancing with the [Up Key] and
returning with the [Down Key]. The figure below shows [Page 1: Speed Loop
Proportional Gain 1].
4. Push the [WR Key] to display the data settings on the next page.
5. Push the [Mode Key] to return to the page selection display screen.
6. Push the [Mode Key] a second time to advance to the next mode.
XP1MA017E
[Setting data: 50Hz]
XP1MA016E
[Page 1: Speed loop proportional gain 1]
XP1MA015E
XP1MA014E
Part 4 Chapter 1 Servo Amplifier Adjustments
Edition 3.0 4-1-5 XP-142E Mechanical Reference
Parameter check mode
1. To change to Parameter check mode, push the Mode Key several times until [PA]
is displayed.
2. The display automatically changes to the page selection display screen shown
below.
3. The page to be monitored is selected by advancing with the [Up Key] and
returning with the [Down Key]. The figure below shows [Group: 0 Page 13:
Torque command filter].
4. Push the [WR Key] for more than one second to display the data settings on the
next page.
5. Push the [Mode Key] to return to the page selection display screen.
6. Push the [Mode Key] a second time to advance to the next mode.
XP1MA021E
[Setting data: 600Hz]
XP1MA020E
[Group 0 Page 13: Torque command filter 1]
XP1MA019E
XP1MA018E
Part 4 Chapter 1 Servo Amplifier Adjustments
Edition 3.0 4-1-6 XP-142E Mechanical Reference