雅马哈YSM切刀更换和保养方法..pdf - 第15页
Service Engineer Service Information SI0907002E - 003 = YS machine’s tape cu tter cleaning and lubrication 15 / 63 Step 4 Disconn ect the harnesse s of the feeder bank at each connector. Draw out the disc onnected harnes…

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
14/63
3.4 Remove the Fixed feeder bank
There are four (4) type of fixed feeder banks – Fixed feeder bank with 60 feeder positions, with 32
feeder positions, with 24 feeder positions and with 14 feeder positions.
The work procedures for the Fixed feeder bank with 24 feeder positions and the Fixed feeder bank
with 14 feeder positions are almost the same.
3.4.1 Remove the Fixed feeder bank with 60 feeder positions
Step 1 Remove the right and left safety CE covers.
Figure 8
Step 2 Remove the cover of the tape cutter driving valve.
Figure 9
Step 3 Disconnect the air hoses of the feeder bank at each quick joint.
Figure 10

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
15/63
Step 4 Disconnect the harnesses of the feeder bank at each connector.
Draw out the disconnected harnesses to the feeder bank side.
Figure 11
Step 5 Remove the plates fastening the tape guide slope to the feeder bank.
Note:
The screw positions are different between the old type tape guide slope and the new one.
Figure 12
Step 6 Check that the feeder bank positioning plates (where a positioning pins are located)
are securely fastened. If loose, fasten them securely.
Caution:
If the feeder bank positioning plates are loose, when you reassemble the removed feeder
bank later on, you cannot position it properly.
Remove the fastening plate.
Remove the fastening plate.

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
16/63
Figure 13