雅马哈YSM切刀更换和保养方法..pdf - 第6页
Service Engineer Service Information SI0907002E - 003 = YS machine’s tape cu tter cleaning and lubrication 6/ 63 1.4 Use the Lock -out padlock General description W hen a service engineer performs m aintenance for the ta…

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
5/63
Safety panel installed
Figure 2
Safety panel removed
When the safety panel is removed, the safety limit switch shuts down power to the tape cutter,
disabling the tape cutter operation. (The default cutter blade position is set to “Close”.)
Warning:
Before removing the safety panel(s), be sure to release the air in the tape cutter by operating the air
supply/shut off switch. If you reverse the steps, the cutter blade might move due to the residual
pressure inside the air hose or the unit and may cause serious injuries.
Figure 3
The tape cutter can be viewed from below.
Safety limit switch
Safety key
Lower safety cover

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
6/63
1.4 Use the Lock-out padlock
General description
When a service engineer performs maintenance for the tape cutter or other parts on the machine,
a bystander may accidentally operate the air supply/shut-off switch, causing the tape cutter or
pneumatic components to be activated and possibly injuring the service engineer.
To prevent this, lock-out padlock is available for the operator to padlock the air supply/shut-off
switch before starting the service work.
Turn the air supply/shut-off switch to shut off the main air supply
Step 1 Turn the air supply/shut-off switch clockwise to shut off the main air supply.
Step 2 Padlock the air supply/shut-off switch using the dedicated holes (see “Note” below).
Step 3 Just to make sure, disconnect the air supply hose.
Note:
Depending on the model, layout of the padlock (keyhole location) and the air supply/shut-off switch vary.
Verify their layout before using the padlock.
Figure 4
Padlock

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
7/63
Turn OFF the air supply/shut-off switch of the tape cutter (light blue colored) and release
the residual pressure
Note:
If there is residual pressure, it is released.
Figure 5
Keyhole for the
lock-out padlock
YS100/YS88
Old
New
Tape cutter air
supply/shut-off valve
Old
New