Service Engineer Service Information SI0907002E - 003 = YS machine’s tape cu tter cleaning and lubrication 60 / 63 5 When the feeder bank position needs to be adjusted mechanically This section desc ribes how to m echani…

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
59/63
4 Check and adjust the pickup positions of the feeders
Step 1 Click the [Utilities] button to start up the CalibSm adjustment utility.
Click the [005 FeederPos] button on the CalibSm main menu.
Step 2 Set the SS feeder pickup position adjustment jig on the machine.
Figure 73
Step 3 Enter the offset values of the jig. Then measure the coordinates of the reference
feeders of all the dismounted feeder banks.
* If the feeder coordinates are out of acceptable range, use the [XYExecute] button to perform
the adjustment.
Step 4 When the measurement and adjustment of all the reference feeder coordinates are
completed, click the [Plate check] button to check all the feeder coordinate data.
Should there be abnormal values (indicated in red), teach the coordinates again and perform
the adjustment.
Note:
See Service Information “SI0907004E YS24, YS24X_Installation and adjustment procedures”
for the detailed operation procedures.
Note:
If feeder coordinate data indicated in red are way out of specified range and/or because of this
simultaneous pickup is not possible, see “5 When the feeder bank position needs to be
adjusted mechanically”.

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
60/63
5 When the feeder bank position needs to be adjusted mechanically
This section describes how to mechanically adjust the feeder bank position when the positioning
plate for the feeder bank is not positioned properly.
5.1 Required items
YAMAHA standard tools
Other tools
Item
Part name
Part number
Qty
Versatile magnet stand bracket
PLATE BASE MAGNET
KJJ-M22JF-10
1
YS24-/YS12-specific magnet stand bracket
MAGNET BASE JIG
KHY-M8808-A0
1
Dial gauge mini-stand (NOGA NF1300)
1
Table 7
5.2 Adjust the feeder bank position mechanically
Step 1 Attach the magnet stand bracket to the machine head.
For the machines equipped with a scan camera, use a magnet stand bracket for YS24 &
YS12. For the machines without a scan camera, use a versatile magnet stand bracket.
Figure 74
Step 2 Attach the dial gauge mini-stand (NF1300) to the magnet stand bracket, and set the dial
gauge to it.
Step 3 Zero the dial gauge on the reference side of the feeder bank.
Note:
The reference side of the feeder bank is on the right side end (viewed from the front side of the
machine).
Step 4 Correct the misalignment of the feeder bank.
1) Loosen the screws fastening the target feeder bank.
2) Loosen the screws fastening the feeder bank positioning block which is NOT on the
reference side.
3) Move the dial gauge from side to side to measure and adjust the feeder bank position
so that it is parallel to the X-axis.
4) Tighten the loosened screws.
Versatile magnet
stand bracket
Magnet stand bracket
for YS24 & YS12
Scan camera

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
61/63
5) Move the dial gauge from side to side again to make sure that there is no misalignment,
and then fully tighten all the loosened screws.
<Specified value>
Parallelism to the X-axis: 0.02 mm or below (0.04 mm around the center of the feeder
bank)
Figure 75
Step 5 Remove the measuring tools from the machine head.
Caution:
Be sure to remove all the measuring tools.
Step 6 Attach the Pickup position adjustment tool on the machine and adjust the feeder
pickup positions.
See “4 Check and adjust the pickup positions of the feeders” for the details.
Reference side
Dial gauge
DO NOT loosen.
Feeder positioning plate