雅马哈YSM切刀更换和保养方法..pdf - 第25页
Service Engineer Service Information SI0907002E - 003 = YS machine’s tape cu tter cleaning and lubrication 25 / 63 3.4.3 Remove t he 24-Feeder exchange carria ge As the F eeder ex change carriage incorporates the f eeder…

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
24/63
Step 13 Remove the tape guide slope Assy.
1) Remove the three (3) fixing screws on the front side of the tape guide slope.
2) Remove the chip component anti-drop cover by removing its two (2) fixing screws.
Warning:
When the tape guide slope is removed, the cutter blade inside will be exposed. Please be extremely
careful not to get injured during the work.
Figure 30
Tape guide slope Assy.
Chip component anti-drop cover

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
25/63
3.4.3 Remove the 24-Feeder exchange carriage
As the Feeder exchange carriage incorporates the feeder bank, if you separate the feeder
exchange carriage from the machine, the feeder bank is detached.
Step 1 Separate the feeder exchange carriage from the machine.
Step 2 Remove the center cover from the feeder exchange carriage for safety.
Figure 31
Step 3 Remove the protective cover of the cutter blade by removing its four (4) fixing screws.
Figure 32
Philips screwdriver
Remove four (4)
screws
Cutter blade
protective cover

Service Engineer
Service Information
SI0907002E-003=YS machine’s tape cutter cleaning and lubrication
26/63
Step 4 Remove the tape guide slope by removing its fixing screws on the right and left sides
of it.
Note:
A washer is used on each fixing screw. Be careful not to lose the washer when removing the
fixing screw.
Figure 33
Step 5 Remove the air hose bypass of the tape guide slope.
Remove the air hose bypass from the bulkhead quick joint at the center of the tape guide
slope.
Note:
The previous-design machines do not have the air hose bypass. Skip this step for the
machines.
Figure 34
Fixing screws
Fixing screws
Air hose bypass