Saving the Production Information Log A production information log can be stored at the machine. Because this occurs on the machine, only the production information for that machine is stored. Procedure 1. At the [Main] …

Setting the Recovery Times
This value is used for the limit of consecutive recovery attempts in response
to pick-up or part inspection errors.
Procedure
1. At the [Main] screen, press [Maintenance A] then [0peration
Settings] to display the [0peration Settings] screen.
2. At the [Recovery Times] (upper right of screen), press the field
to display the numeric key. Enter the desired recovery times,
then press [CR].
3. Press [Close] to return to the [Main] menu.
Production Information Display
Production information can be displayed at the machine. Because this occurs
on the machine, only the production information for that machine displays.
Procedure
1. At the [Main] screen, press the [Production] button.
2. Press the [Production Data] button.
Chapter 3: Preparing for Production
TUT-XP142-1.1E
3-5XP-142E Operator’s Guide

Saving the Production Information Log
A production information log can be stored at the machine. Because this
occurs on the machine, only the production information for that machine is
stored.
Procedure
1. At the [Main] screen, press the [Production] button.
2. Press the [Production Data] button. The user can then specify
the desired “log save” (new log registration start) timing.
Note: Events are always being registered in the log, and the log is saved to a
file at the following times:
1. Whenever the user presses the [Production Info Save] button.
2. When the machine is shut down.
3. When a recipe is selected (recipe change).
4. When the date is changed.
Chapter 3: Preparing for Production
TUT-XP142-1.1E
3-6 XP-142E Operator’s Guide

Changing the Production Program
Follow the procedure below to change the production program.
Note: Refer to the host system operation manual for the procedure for
transmitting production programs.
Procedure
1. At the [Main] screen, press [Production] then [Select Program]
to display the [Select Program] dialog box.
2. Click the [▼] button to select the location where the program
file is saved.
Hard disk: /sd0
Floppy disk: /fd0
A list of the available programs is displayed in a dialog box.
3. Select the desired program from the list, then press the
[Download] button to load that program. The name of the
loaded program displays on the title bar at the top of the
screen, indicating that this program is now active.
Note: If the nozzle arrangement in the program does not match the nozzles at
the machine, a warning message will be displayed. To produce with the
nozzles in the machine, press [YES]. Press [NO] and the [Nozzle
Editor] screen is displayed. Please refer to the XP-142E System
Reference manual for an explanation of the nozzle editor.
3.2 Production Programs
Chapter 3: Preparing for Production
TUT-XP142-1.1E
3-7XP-142E Operator’s Guide