XP-142E Operator's Guide-TUT-XP142-1.1E.pdf.pdf - 第52页
Point The gauge chip parts, which are used for nozzle rotation center measurements and mount feedback corrections, are located in a prescribed position, and should be cleaned regularly to ensure stable measurements and c…

Point
Parts are picked up by air suction. Because air is sucked through the nozzle,
minute dust, glue particles, etc., can build up inside the nozzle tube causing
clogging. Such clogging reduces the nozzle suction, causing problems when
picking up parts. The nozzle tube should be cleaned out regularly, or if
clogging problems occur.
Procedure
Use an appropriately sized drill bit to remove foreign matter from inside the
nozzle tube.
Conduct a nozzle size check ( [Production] - [Nozzle Editor] - [Size Check]).
If the nozzle is dirty the nozzle size check may fail. In this case, clean the
tip of the nozzle with a rag soaked in alcohol.
XP1MC203E
Nozzle
Drill bit
7.3 Cleaning the Nozzle Interior
(Every Week)
Chapter 7: Maintenance
TUT-XP142-1.0E
7-4 XP-142E Operator’s Guide

Point
The gauge chip parts, which are used for nozzle rotation center
measurements and mount feedback corrections, are located in a prescribed
position, and should be cleaned regularly to ensure stable measurements and
corrections.
Procedure
WARNING
Turn off the main circuit breaker before performing
this procedure.
Wipe the surface with a soft brush (such as is used for camera lenses).
XP1MC204E
Gauge chip parts
7.4 Cleaning the Gauge Chip Parts
(Every Week)
Chapter 7: Maintenance
TUT-XP142-1.0E
7-5XP-142E Operator’s Guide

Point
The vacuum pump is equipped with a dust filter. This filter should be
cleaned/replaced regularly to ensure stable part pick-ups.
Procedure
1. Remove the MFU from the rear of the machine (side 2).
2. Turn the machine power off.
WARNING
Turn off the main circuit breaker before performing
this procedure.
3. Disconnect the air supply, and confirm that the pressure is 0.
XP1MC205E
0
7.5 Cleaning the Vacuum Pump Filter
(Every Week)
Chapter 7: Maintenance
TUT-XP142-1.0E
7-6 XP-142E Operator’s Guide