00194103-01.pdf - 第101页

User Manual SIPLAC E F5 HM 3 Technical data Software Version SR.408.xx 03/ 2006 US Edition 3.12 PCB dual conveyor 101 3.12.10 M aintenance The indivi dual conv eyor belts and th e additiona l lifting table req uire the s…

100%1 / 230
3 Technical data User Manual SIPLACE F5 HM
3.12 PCB dual conveyor Software Version SR.408.xx 03/2006 US Edition
100
3.12.8 Synchronous transport mode
3.12.8.1 Description
In synchronous mode, two PCBs of the same size are simultaneously moved to the placement
position. They must be processed as a common panel.
In this way, the top and bottom of a PCB can be processed on a single line, and the time required
to transport the PCB is shorter since two PCBs are always transported at the same time.
3.12.8.2 Function
PCBs on conveyor tracks 1 and 2 are moved synchronously onto the conveyor sections (i.e. the
conveyors are controlled synchronously, but independently of one another). The components to
be placed on conveyor tracks 1 and 2 must be organized into a panel via two subpanels. (See
the SIPLACE Pro computer user manual).
If only one conveyor track (or center conveyor) is full when the placement sequence starts, the
subpanel on this section will be identified as “not for placement”.
3.12.9 Technical data for the dual conveyor
3
PCB format 50 x 50 mm² to 460 x 216.5 mm²
2" x 2" to 18" x 8.5"
Optional:
up to 508 x 216.5 mm²
up to 20" x 8.5"
PCB thickness 0.3 to 4.5 mm
Max. PCB warpage up: 4.5 mm - PCB thickness
down: 0.3 mm + PCB thickness
clearance on PCB underside 25 mm (standard), 40 mm (option)
PCB transport height 830 ± 15 mm (standard)
900 ± 15 mm (option)
930 ± 15 mm (option)
950 ± 15 mm (SMEMA option)
Type of interface Siemens (standard), SMEMA (option)
Component-free PCB handling edge 3 mm
PCB changeover time 2.5 s
Fixed conveyor side Right (standard), left (optional)
Components on each conveyor synchronous: same or different, asynchronous: same
PCB width on each conveyor synchronous: same or different, asynchronous: same
User Manual SIPLACE F5 HM 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.12 PCB dual conveyor
101
3.12.10 Maintenance
The individual conveyor belts and the additional lifting table require the same maintenance as the
standard conveyor. Each conveyor belt must be maintained as described in the maintenance
instructions.
3
3
Bad fiducial detection Synchronous: impossible, asynchronous: possible
Automatic width adjustment Synchronous: impossible, asynchronous: possible
3 Technical data User Manual SIPLACE F5 HM
3.12 PCB dual conveyor Software Version SR.408.xx 03/2006 US Edition