00194103-01.pdf - 第81页
User Manual SIPLAC E F5 HM 3 Technical data Software Vers ion SR.408.xx 03/2006 U S Edition 3.7 Controls 81 3.7 Controls 3.7.1 Position of the controls 3 Fig. 3.7 - 1 Overview of the modules - controls (1) Op erator pane…

3 Technical data User Manual SIPLACE F5 HM
3.6 Dimensions and weight of the placement system Software Version SR.408.xx 03/2006 US Edition
80
3.6.5 Dimensions of the placement machine with WPC and component trolley
3
Fig. 3.6 - 4 Dimensions of the placement machine with WPC and component trolley in millimeters
3
3

User Manual SIPLACE F5 HM 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.7 Controls
81
3.7 Controls
3.7.1 Position of the controls
3
Fig. 3.7 - 1 Overview of the modules - controls
(1) Operator panel, input side (2) EMERGENCY STOP button
(3) Start button (white) (4) Stop button (black)
(5) Main power switch (6) Operator panel, output conveyor
(7) EMERGENCY-STOP button (8) Start button (white)
(9) Stop button (black) (10) Component counter
(11) Key switch (12) Computer
(13) Indicator lamp (14) Touchscreen monitor
(15) Keyboard with trackball

3 Technical data User Manual SIPLACE F5 HM
3.7 Controls Software Version SR.408.xx 03/2006 US Edition
82
3.7.2 Description
All the controls can be reached by a 1.60 m tall person. 3
Main power switch 3
The main power switch is used to switch the power supply to the placement system on and off. 3
RISK OF DEATH
Some parts inside the placement system carry potentially lethal voltages - even when switched
off at the main switch. 3
Key switch 3
In normal mode, the key switch is set to "0". The key should be removed and kept in a safe place.
It must only be turned to position "I" (set-up mode) by authorized personnel, and then only for
certain maintenance and servicing work. 3
Stop button 3
This button is used to stop the placement system. 3
Start button 3
This button starts the placement system after it has been switched on or after faults have been
eliminated. 3
EMERGENCY-STOP button 3
The EMERGENCY STOP button latches in the ON position when pressed. The power supply to
the gantry axes, the star axes, CO tables, conveyor belts and the used tape cutters is interrupted.
Turn the button to release it. 3
Component counter 3
The component counter displays the number of components processed. 3
Station computer, monitor and keyboard 3
The station computer, monitor and keyboard are mounted on a pivoting console on the place-
ment system’s central crossbeam. The station computer is a desktop model with a Pentium pro-
cessor. The operating system is WINDOWS XP. The SIPLACE graphical user interface, which is
based on the Windows standard, is used to operate and monitor the placement system. A color