00194103-01.pdf - 第173页
User Manual SIPLAC E F5 HM 7 Options Software Vers ion SR.408.xx 03/2006 U S Edition 7.1 Nozzle changer for the 12-segm ent Collect&Place head 173 7 Options 7.1 Nozzle changer for the 1 2-segment Collect& Place h…
6 Component handling User Manual SIPLACE F5 HM
6.5 Waffle-pack changer Software Version SR.408.xx 03/2006 US Edition
172

User Manual SIPLACE F5 HM 7 Options
Software Version SR.408.xx 03/2006 US Edition 7.1 Nozzle changer for the 12-segment Collect&Place head
173
7 Options
7.1 Nozzle changer for the 12-segment Collect&Place
head
7.1.1 Overview
A nozzle changer for the 12-segment Collect&Place head may be installed to the left of the PCB
conveyor without losing any locations. This enables the nozzle configuration to be changed
quickly, thus allowing the Collect&Place head to be quickly adapted to the needs of the place-
ment process.
The nozzle changer consists of at least one, and up to seven magazines, each with twelve noz-
zle garages (see Fig. 7.1 - 1
). The magazines are seated on a common support. Each magazine
is centered using two parallel pins and fixed in place with a screw.
7.1.2 Technical data - Nozzle changer for the 12-segment Collect&Place head
Nozzle changer for the 12-segment Collect&Place head
Dimensions (length x width x height) 560 x 60 x 46 mm³
Number of nozzle garages Min. 12 / max. 84
Nozzle types 9 xx
Time required to open and close the locking plate < 200 ms
Capacity of the reject bin Approx. 50 nozzles
Pneumatic circuit Compressed air line 5.2 bar

7 Options User Manual SIPLACE F5 HM
7.1 Nozzle changer for the 12-segment Collect&Place head Software Version SR.408.xx 03/2006 US Edition
174
Fig. 7.1 - 1 Nozzle changer for the 12-segment Collect&Place head, overview
7.1.3 Mode of operation
The nozzles are seated in nozzle garages and are held in place by a movable locking plate. The
locking plate can be moved 6 mm by a pneumatic cylinder. All the nozzles are either clamped or
released, depending on the position of the plate. The default position of the locking plate, i.e. if
there is no nozzle change in progress, is "closed".
(1) Magazine
(2) Nozzle discarding device
(3) Reject bin for discarded nozzles
(4) Nozzle changer, base
(5) Nozzle changer, base