00194103-01.pdf - 第76页
3 Technical data User Manual S IPLACE F5 H M 3.5 Technical data – Ratings S oftware Version SR.408.xx 03/2006 US Edition 76 3.5 T echnical da t a – Ratings 3.5.1 T echnica l dat a – El ectrical ratings 3 3.5.2 T echnical…

User Manual SIPLACE F5 HM 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.4 Electrical and pneumatic connection points
75
DANGER
The placement system is supplied with 3 x 400 VAC or 3 x 208 VAC US version) ± 5%, 50/60 Hz
main power voltage. This means that some parts of the system carry potentially lethal voltages
- even when switched off at the main power switch. Death, serious injury or considerable damage
may result if this automatic placement system is handled incorrectly. 3
WARNING
Never disconnect compressed air lines while they are pressurized. Risk of injury. 3

3 Technical data User Manual SIPLACE F5 HM
3.5 Technical data – Ratings Software Version SR.408.xx 03/2006 US Edition
76
3.5 Technical data – Ratings
3.5.1 Technical data – Electrical ratings
3
3.5.2 Technical data – Compressed air supply
3
3.5.3 Technical data – Compressed air specification
Maximum particle size by density, based on ISO/DIS 8573-1 (class 1) 3
3.5.4 Technical data – Noise emissions
3
3.5.5 Technical data – permissible ambient factors
3
Supply voltage 3 x 400 VAC ± 5 %; 50/60 Hz (Europe)
3 x 208 VAC ± 5 %; 50/60 Hz (U.S.A.)
Fuses 3 x 16 A (3 x 400 VAC, 3 x 208 VAC)
Nominal apparent power 1.3 kVA
Rated current consumption 3.4 A / 3 x 400 VAC
Power failure Max. 20 msec
Compressed air pressure min. 5.5 bar, max. 8 bar
Compressed air consumption 300 st. l/min. (6-segment Collect&Place head)
400 st. l/min. (12-segment Collect&Place head)
Operating pressure Set to 5.2 bar ± 0.1 bar
Connection 1/2"
Particle size 0.1 µm
Particle density 0.1 mg/m³
Maximum oil content (class 1) Particle density 0.01 mg/m³
Pressure dewpoint (class 4) Dewpoint +3°
Max. noise generated 74dB(A)
Room temperature Between 15°C and 35°C

User Manual SIPLACE F5 HM 3 Technical data
Software Version SR.408.xx 03/2006 US Edition 3.6 Dimensions and weight of the placement system
77
3.6 Dimensions and weight of the placement system
3.6.1 Dimensions of the placement system with component trolley
3
Fig. 3.6 - 1 Dimensions of the placement machine with component trolley
3.6.2 Technical data - Dimensions, weight
3
Atmospheric humidity 30 to 80%
(but no higher than 45% on average in order to prevent
any possibility of condensation on the machine).
Length 1587 mm including conveyor belts
Width 2455 mm including brackets
Height with warning lamp 1836 mm standard height
Ground clearance 120 mm standard height
Weight of basic module 1500 kg
Weight fully equipped Approx. 2000 kg