00194103-01.pdf - 第41页

User Manual SIPLAC E F5 HM 2 Operational safety Software Vers ion SR.408.xx 03/2006 U S Edition 2.2 Warning labels 41 2.2.4 W arning label s on th e waffle-p ac k changer 2 Fig. 2.2 - 9 Warning labels on t he waffle-pack…

100%1 / 230
2 Operational safety User Manual SIPLACE F5 HM
2.2 Warning labels Software Version SR.408.xx 03/2006 US Edition
40
Sticker on feeder module (enlarged)
DANGER 2
Capacitors based on metal-powder, such as tantalum capacitors, may only be processed with
feeder modules that are identified with this sticker. 2
2.2.3 Warning label "Danger of crushing" on the component trolley
2
Warning label "Danger of Crushing" (number per component trolley: 2)
2
Fig. 2.2 - 8 Warning label Danger of crushing on the component trolley
Warning label Danger of crushing, item no. 00343357-01
2
2
2
WARNING DANGER OF CRUSHING!
Do not place your hands in the danger area
when lowering the component feeder table.
DANGER OF CRUSHING!
User Manual SIPLACE F5 HM 2 Operational safety
Software Version SR.408.xx 03/2006 US Edition 2.2 Warning labels
41
2.2.4 Warning labels on the waffle-pack changer
2
Fig. 2.2 - 9 Warning labels on the waffle-pack changer
2
Warning label WPC, part no. 00321262-02 (number per WPC:1)
WARNING!
Remove IC vision illumination unit before
docking or undocking the machine!
> DANGER OF A CRASH <
Move the waffle-pack changer only over flat
and level floors!
The waffle-pack storage unit must be in its
LOWEST POSITION before transportation!
> DANGER OF OVERTURNING! <
2 Operational safety User Manual SIPLACE F5 HM
2.3 Laser classification Software Version SR.408.xx 03/2006 US Edition
42
2
Warning label (number per WPC: 4)
2
2
2
2.3 Laser classification
PLEASE NOTE: 2
Modules in laser classes 1 and 1M are not identified.
2.3.1 Laser class 1
2
2
2.3.2 Laser class 2
The following modules are assigned to laser class 2:
PCB barcode scanner
Coplanarity laser module
2
2
2
2
DANGEROUS VOLTAGES!
The identified parts are under mains voltage.
Disconnect the machine from the main power supply before ser-
vicing it!
NAFTA region: RISK OF ELECTRIC SHOCK OR BURN!
All installed camera systems and the whole machine when ready
for operation are assigned to laser class 1.
The laser classes are determined as per DIN EN 60825-1:2001.
2
Laser radiation
Do not look into beam!