TRANSPORTATION - MAJOR RELOCATION MACHINE SUPPLIES AND ENVI RONMENTAL CONDITIONS 43.36 Technical Reference Manual Chapter Issue 2, Ju l 16 MACHINE SUPPLIES AND ENVIRONMENT AL CONDITIONS Electrical The machine operates on…

TRANSPORTATION - MAJOR RELOCATION
RELOCATION
Chapter Issue 2, Jul 16 Technical Reference Manual 43.35
7. Adjust the height of each foot to approximately the same height, secure in
place by tightening the nuts.
NOTE
Leg spacers are shown here, but they are not used until the machine has
been moved to the designated position.
8. Move the machine to its designated position.
Leg Spacers
(2 shown)
Machine Mounting Foot
M24 Locking Nuts
Machine Frame
Leg Adjusting Nut

TRANSPORTATION - MAJOR RELOCATION
MACHINE SUPPLIES AND ENVIRONMENTAL CONDITIONS
43.36 Technical Reference Manual Chapter Issue 2, Jul 16
MACHINE SUPPLIES AND ENVIRONMENTAL CONDITIONS
Electrical
The machine operates on 100V to 240V ±10% 50/60Hz single phase ac mains.
ASM recommends a power supply capacity of 2.4KVA or greater.
ASM requires additional machine supply protection with the tment of an external double pole
circuit breaker conforming to national, federal or local legislation. ASM recommends that the
external circuit breaker is tted near the DEK printer and within easy reach of the operator. Use
the following table to ensure the recommended circuit breaker is used:
Pneumatic Supply
The machine requires a pneumatic supply of clean, non lubricated air which should maintain a
minimum pressure of 5 Bar and a maximum of 8 Bar. The printer requires 5 litres/minute for
general use and a maximum of 226 litres/minute at 6 Bar.
The air should be to ISO 8573.1 standard, quality class 2.3.3.
Operating Conditions
The DEK printer must only be operated in the following operating envelope:
Indoors only
Unsuitable for use in wet locations
Temperature = 5 to 40°C (40 to 105°F)
Humidity = Maximum 80% Relative Humidity (non condensing)
Altitude = Maximum 2,000 metres (6,500 feet)
Pollution must comply to Degree 2
If the equipment is used in a manner not specied by the manufacturer, the protection provided
by the equipment may be impaired.
This equipment should be installed in accordance with the Installation Manual. ASM absolves
itself of all responsibility if the machine is not used within its operating envelope or for its
intended purpose.
NOTE
An over current circuit breaker protects the machine's internal wiring and components from
overheating or catching re during fault conditions. Under no circumstances must a circuit
breaker of value greater than 25 Amps be tted.
Transient overvoltages must not exceed those dened in Cat 2 of IEC 60364-4-443.
Voltage uctuations must not exceed 10% of nominal voltage.
115 Volts115 Volts 230 Volts
With Internal Vacuum UnitWithout Internal Vacuum Unit
230 Volts
Machine Current Consumption (approximately)
Value of Wall Mounted Circuit Breaker
20 Amps
25 Amps
6 Amps
10 Amps
10 Amps
13/16 Amps
3 Amps
4/6 Amps

TRANSPORTATION - MAJOR RELOCATION
MACHINE SUPPLIES AND ENVIRONMENTAL CONDITIONS
Chapter Issue 2, Jul 16 Technical Reference Manual 43.37
Machine Footprints
Figure 43-7 Style 1 Covers
R0630.
Max dimension from
pivot point
360
1150
Transfer Height 960
980 max)
(840 min to
Side View (Right)
1345
( min to 13 2 max)1102 6
1106
(1352 min to 1492 max)
141
Front View
1913
(1 min to 1 max)834 974
1471.5
Plan View
606
Front of
board
1758
1334
Weight
Boxed - 8 kg, Unboxed - 6 kg10 60
(Dependent upon configured options
selected with the machine)
Note
All dimensions
in millimetres
Board transfer
height 8
- 980 mm40
Screen load height 925 - 1
065 mm