STINGER
OVERVIEW
Chapter Issue 2, Aug 14 Technical Reference Manual 38.5
Operation Regulated air is supplied to the rear of the syringe, forcing an internal plunger
to compress the adhesive. The auger body fills with adhesive and the auger
valve screw (Archimedes screw) is rotated, providing a stirring motion that
‘works’ the adhesive; this action disperses any air bubbles that may be present.
Figure 38-2 Exploded View of the Dispense Mechanism
The unit can be programmed to purge the contents of the syringe, ensuring
consistency, prior to a production run. Externally, a consumable level sensor
detects the level of the adhesive in the syringe and warns the operator when
the level is low. A laser can be programmed to take height readings across the
top surface of the product; the information gained, is used to adjust the dispense
height, thereby increasing the consistency during the dispense cycle.
For detailed set up and operation procedures refer to manual, Stinger, a guide
to adhesive dot dispensing - Part Number 198825.
Auger Valve Screw
Auger Body
Syringe Head
Tip

STINGER
ELECTRICAL SHEMATIC
38.6 Technical Reference Manual Chapter Issue 2, Aug 14
ELECTRICAL SHEMATIC
M37 PSU
IBUS PC
4
3
4
4
M37PL10
8PL34
M48SK02
M48PL07
M48SK07
M48PL01
M48PL05
M48PL06
M48SK06
M48PL08
M48PL09
M48SOL01
Air Feed
Pneumatic Cylinder
Stinger
Enclosure
Stinger
Board
Laser Sensor
M48SE01
Consumable
Level Sensor
M48SE02
Dispense
Motor
M48M01
Z Axis
Motor (Linear Actuator)
M48M02

STINGER
ADJUSTMENTS AND SETTINGS
Chapter Issue 2, Aug 14 Technical Reference Manual 38.7
ADJUSTMENTS AND SETTINGS
WARNING
BOARD CLAMPS. EXTREME CARE MUST BE EXERCISED WHEN WORKING IN
THE TOOLING AREA OF THE MACHINE TO AVOID INJURY. THE FOILS ON THE
FRONT AND REAR BOARD CLAMPS ARE VERY SHARP.
WARNING
COMPRESSED AIR. COMPRESSED AIR SHOULD NEVER IMPINGE UPON THE
BODY. PORTS, PIPES, ETC MUST NEVER BE BLOCKED BY HAND. BEFORE
CONNECTING OR DISCONNECTING ANY PNEUMATIC COMPONENTS, ENSURE
THE COMPRESSED AIR SUPPLY HAS BEEN DISSIPATED AND DISCONNECTED
FROM THE MACHINE.
CAUTION
EQUIPMENT SERVICING. THE LASER DOES NOT CONTAIN USER
SERVICEABLE PARTS. OPENING THE UNIT COULD CAUSE MIS-ALIGNMENT
OF THE LASER, THIS MAY MAKE THE EQUIPMENT DANGEROUS TO OPERATE.
CAUTION
RADIATION. RISK OF INJURY TO THE EYES DUE TO LASER LIGHT BEING
PRESENT IN THE VICINITY OF THE LABEL. DO NOT LOOK AT THE LIGHT
SOURCE OR REFLECTIONS FROM A SURFACE.
WARNING
HARMFUL SUBSTANCES. CLEANING WIPES AND CLEANING SOLUTIONS MAY
CONTAIN SUBSTANCES HAZARDOUS TO HEALTH. WHEN USING CLEANING
WIPES AND CLEANING SOLUTIONS THE MANUFACTURERS’ SAFETY DATA
SHEETS MUST BE STRICTLY ADHERED TO.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. SAFETY GLOVES MUST BE WORN.
MANDATORY
TOXIC CHEMICALS MAY BE PRESENT. EYE PROTECTION MUST BE WORN.
Idle height is the position to which the needle tip is set, between dispensing
actions. The dispenser moves to its dispense site, after dispensing it is moved
to the idle position, before moving on to the next location. There are two
procedures:
• Manual
• Automatic