00196062-03_SM_LDU-X_EN.pdf - 第48页

4 Service Work 4.2 Replacing Spare Parts 48 Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 4.2.23 Replacing the handle Overview Spare parts kit "Handle" [03062471-xx] Legend 1. Handle [03062471-xx] wi…

100%1 / 78
4 Service Work
4.2 Replacing Spare Parts
Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 47
4.2.22 Replacing the cover
Overview
Cover [03062461-xx]
Equipment required
Spare part: cover [03062461-xx]
Removal
The cover is fixed by two magnets.
Remove the old cover.
Installation
Make sure that the new cover is fitted with
the two warning labels and the warning
strip.
Position the new cover on the top of the
LDU-X so that the warning strip points to-
wards the dip plate.
4 Service Work
4.2 Replacing Spare Parts
48 Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.2.23 Replacing the handle
Overview
Spare parts kit "Handle" [03062471-xx]
Legend
1. Handle [03062471-xx] with holes
drilled for grub screws
2. Screws ISO4762–M3x6-8.8, gal-
vanized [03007733-xx] (2x)
Equipment required
Standard tools
Loctite 222 (screw locking varnish)
Allen key size 2.5
Spare parts:
Handle [03062471-xx]
Screws ISO4762–M3x6-8.8, galvanized [03007733-xx] (2x)
Removal
Place the LDU-X down on its left-hand
side, on a stable, clean and even sur-
face.
Open the flap(1).
4 Service Work
4.2 Replacing Spare Parts
Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 49
Remove the two screws marked in the
diagram(2).
Remove the handle(3).
Installation
Fit the new handle(1) on the outside
of the flap, as shown in the dia-
gram(2).
Position the new handle so that the
threaded holes in the handle are over
the two holes in the flap.
Coat the two screws with "Loctite 222
locking varnish".
Push the screws(3) on the inner side
of the flap into the holes provided.
Fasten the handle to the flap, using
the two screws(3).