00196062-03_SM_LDU-X_EN.pdf - 第48页
4 Service Work 4.2 Replacing Spare Parts 48 Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 4.2.23 Replacing the handle Overview Spare parts kit "Handle" [03062471-xx] Legend 1. Handle [03062471-xx] wi…

4 Service Work
4.2 Replacing Spare Parts
Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 47
4.2.22 Replacing the cover
Overview
Cover [03062461-xx]
Equipment required
●
Spare part: cover [03062461-xx]
Removal
The cover is fixed by two magnets.
► Remove the old cover.
Installation
► Make sure that the new cover is fitted with
the two warning labels and the warning
strip.
► Position the new cover on the top of the
LDU-X so that the warning strip points to-
wards the dip plate.

4 Service Work
4.2 Replacing Spare Parts
48 Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.2.23 Replacing the handle
Overview
Spare parts kit "Handle" [03062471-xx]
Legend
1. Handle [03062471-xx] with holes
drilled for grub screws
2. Screws ISO4762–M3x6-8.8, gal-
vanized [03007733-xx] (2x)
Equipment required
●
Standard tools
●
Loctite 222 (screw locking varnish)
●
Allen key size 2.5
●
Spare parts:
– Handle [03062471-xx]
– Screws ISO4762–M3x6-8.8, galvanized [03007733-xx] (2x)
Removal
► Place the LDU-X down on its left-hand
side, on a stable, clean and even sur-
face.
► Open the flap(1).

4 Service Work
4.2 Replacing Spare Parts
Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017 49
► Remove the two screws marked in the
diagram(2).
► Remove the handle(3).
Installation
► Fit the new handle(1) on the outside
of the flap, as shown in the dia-
gram(2).
► Position the new handle so that the
threaded holes in the handle are over
the two holes in the flap.
► Coat the two screws with "Loctite 222
locking varnish".
► Push the screws(3) on the inner side
of the flap into the holes provided.
► Fasten the handle to the flap, using
the two screws(3).