4 Service Work
4.6 Maintenance: greasing the spindle and guidance
76 Service Manual SIPLACE LDU-X Linear Dipping Unit 11/2017
4.5.6 The axes won't move
Errors: The axes suddenly stop while moving.
Display: X axis or Y axis error
Status display: Red LED lights up
Cause: The control circuit for positioning is overloaded and the control system stops
the movement.
Solution: Reduce the speed of the axis concerned (see "Parameters").
Increase the "tracking error" parameters.
4.5.7 Position Error
Errors: The axes suddenly stop while moving.
Display: Position error
Status display: Red LED lights up
Cause: The control circuit for positioning is overloaded and the control system stops
the movement.
Solution: Reduce the speed of the axis concerned (see "Parameters").
Increase the "tracking error" parameters.
4.5.8 Step Loss
Errors: The axes suddenly stop while moving.
Display:
Status display: Red LED lights up
Cause: The control circuit for positioning is overloaded and the control system stops
the movement.
Solution: Reduce the speed of the axis concerned (see "Parameters").
Increase the "tracking error" parameters.
4.6 Maintenance: greasing the spindle and guidance
All LDU-X guides and spindles must be greased every 6 months or more often if required.
Grease with ISOFLEX Topas 5051 (03078517-04).
Grease the guidance(1) and the
spindle(2) evenly and along the whole
length.
Also grease the spindle and guidance on
the other side of the LDU-X.