DEK INFINITY USER MANUAL.pdf.pdf - 第116页
INFINITY 0$&+,1( 352*5$ 00,1* 63&&21),* 85$7,21 1.114 User Manual Software Versi on 7 The table below illustrates how the use of the following SPC Configuration parameters can vary the sampling of SPC Outpu…

INFINITY
0$&+,1(352*5$00,1*
63&&21),*85$7,21
Software Version 7 User Manual 1.113
SPC CONFIGURATION
When the cursor on the Edit Current Process Parameters page highlights the SPC
Configuration option and Incr. or Decr. are pressed an SPC Configuration
Window opens and two extra menu options become available:
Configuration
Window
The configuration window allows the user to setup the machines SPC operation.
Data Output Rate Two rates of data output are available as follows:
Every Cycle - Outputs SPC data every cycle except for the camera data, which
is output dependant upon the settings of the parameters start rate, sample rate
and start rate limit.
On Inspect - Outputs all SPC data at a rate dependant upon the settings of the
parameters start rate, sample rate and start rate limit.
Start Rate Limit Sets the amount of SPC output cycles at the start rate. When this limit is reached
the sample rate parameter becomes the active SPC output rate. The range is 0-
100, where 0 = continuous SPC output at the start rate.
NOTE
Setting both start rate limit and sample rate to zero causes continuous SPC
output at the start rate.
Start Rate Sets the initial SPC output rate, for setting up a line. If start rate is set to 10, SPC
data is output every 10 cycles until the start rate limit is reached, when the rate
becomes that set in the sample rate parameter. The range is 1-100.
Sample Rate Sets the rate of SPC output after the start rate limit has been reached. The range
is 0-100, where 0 = continuous SPC outputs at start rate. If sample rate is set to
15, SPC data is output every 15 cycles after the start rate limit is reached.
Edit
Outputs
Edit
Limits
Next Previous Incr. Decr. Exit
SPC Configuration Page
DATA OUTPUT RATE
START RATE
SAMPLE RATE
START RATE LIMIT
SPC DATA MODE
SPC FORMAT
UPDATE ON START-UP
ALIGN INSPECT MODE
EVERY CYCLE
1
10
10
NONE
WINDOWS
NO
PRE PRINT
cycles
cycles
cycles

INFINITY
0$&+,1(352*5$00,1*
63&&21),*85$7,21
1.114 User Manual Software Version 7
The table below illustrates how the use of the following SPC Configuration
parameters can vary the sampling of SPC Output Parameters from the machine:
• Data Output Rate
• Start Rate
• Sample Rate
• Start Rate Limit
NOTE
Machine Data and Camera Data are defined in the table in SPC Output
Parameters section.
SPC Data Mode Six modes of data transfer are available as follows:
• None - No SPC data is output at any time.
• Remote - The data is written to a file called READINGS.DEK located on
a remote network drive.
• Serial - The data is output from the machines serial SPC port.
• Disk - The data is written to a file called READINGS.DEK located on the
machines local drive.
• Serial + Remote - Outputs data in both modes.
• Serial + Disc - Outputs data in both modes.
SPC Format All data, irrespective of SPC data mode, is in the selected SPC format, options
are: DOS or Windows.
1 2 3 4 5 6 7 8 9 10111213141516171819202122232425262728293031323334353637383940
Machine Cycles
Start Rate
Sample Rate
Start Rate Limit
Every Cycle
Every Cycle
Every Cycle
Every Cycle
Every Cycle
On Inspect
On Inspect
On Inspect
On Inspect
On Inspect
100
1
00
1510
1510
2510
2510
5120
5
120
1510
15
10
X
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XX
X
0000000000000000000000000000000000000000
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
0000000000000000000000000000000000000000
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
00000 0 0 0 0 0 0
XXXXX X X X X X X
00000 0 0 0 0 0 0
XXXXXX
X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
0 0 0 000000000000000000000
X X X XXXXXXXXXXXXXXXXXXXXX
0 0 0 000000000000000000000
XXXXX X X X
00000 0 0 0
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
00000 0 0 0
XXXXXXXXXX X X X X X X
0000000000 0 0 0 0 0 0
X
XXXXXXXX
X
XXXXXXXXXXXXXX XXXXXXXXXXXXXX
X
0000000000
0
000 0
X
0
Machine DataX
0
Legend
Camera Data

INFINITY
0$&+,1(352*5$00,1*
63&&21),*85$7,21
Software Version 7 User Manual 1.115
Update on Start-up The windows format contains the header data which has all the display informa-
tion for the real time plots, including nominals, tolerances and control limits.
The DOS format does not contain this header data. Two options are available as
follows:
• Yes - Use if SPC format is set to DOS, header data is sent on start up.
• No - Use if SPC format is set to windows.
Align Inspect Mode Four modes of alignment inspection are available as follows:
1. None - No fiducial alignment information is output at any time.
2. Pre Print - Board and screen fiducial alignment information is taken after
alignment but before the board is printed.
3. Post Print - Board and screen fiducial alignment information is taken after
the board is printed.
4. Pre + Post Print - Board and screen fiducial alignment information is taken
before and after the board is printed.
The Next and Previous keys are used to move through the parameters.
The Incr. and Decr. keys change the parameter values.
Selecting the Edit Outputs key opens an SPC Output Parameters window and
allows the user to decide which SPC parameters are output to the SPC data file
READINGS.DEK (see the SPC Output Parameters section).
The Edit Limits key opens an Edit SPC Limits window (see the Edit SPC Limits
section), the window gives the operator the ability to set nominal, minimum and
maximum limits for the various SPC parameters and define whether the machine
stops when a limit is exceeded.