INFINITY &21680$ %/(5(3/ (1,6+0(1 76 352)/2: 9.48 User Manual Software Versi on 7 Retent ion System Replacem ent Due to wear over prolonged periods, it i s necessary to replace the wiper foils and skis. An obvious i…

100%1 / 356
INFINITY
&21680$%/(5(3/(1,6+0(176
352)/2:
Software Version 7 User Manual 9.47
6. If the set preference is set to pause, the tricoloured beacon shows red and the
following window is displayed:
7. Select Refill Paste (F1). The message Open the cover and change the
ProFlow cassette. is displayed.
8. Select Open Cover (F2).
9. Carry out Steps 19-33 of Prior to a Print Run procedure, earlier in this
section.
10.Select Continue (F1). The print run resumes.
11. If the set preference is set to suspend, the tricoloured beacon shows red and
the following window is displayed:
12.Select Refill Paste (F1). The message Open the cover and change the
ProFlow cassette. is displayed.
13.Select Open Cover ((F2).
14.Carry out Steps 19-33 of Prior to a Print Run procedure, earlier in this
section.
15.Select Continue (F1). The print run resumes.
Pause on Warning
Print Medium Low. Please replenish.
Refill
Paste
Defer
Continue
Open
Cover
Continue
Open
Cover
Suspend on Warning
Print Medium Low. Please replenish.
Refill
Paste
End
Run
Continue
Open
Cover
Continue
Open
Cover
INFINITY
&21680$%/(5(3/(1,6+0(176
352)/2:
9.48 User Manual Software Version 7
Retention System
Replacement
Due to wear over prolonged periods, it is necessary to replace the wiper foils and
skis. An obvious indication of blade deterioration is print medium left deposited
on the screen after a print cycle, an example of this indication is shown in the
figure below.
Figure 9-1 Example Of Proflow Wiper Wear
Replace the wipers and skis as follows:
WARNING
SOLDER PASTE AND SOLVENTS. WHEN USING OR HANDLING ANY SOLDER
PASTE OR SOLVENT FORMULATION THE MANUFACTURERS RECOMMEND
SAFETY PRECAUTIONS MUST BE STRICTLY ADHERED TO.
WARNING
PROTECTIVE CLOTHING. APPROVED PROTECTIVE CLOTHING SHOULD BE
WORN BY SOLDER PASTE AND SOLVENT HANDLERS AT ALL TIMES TO
ELIMINATE FUME INHALATION, EYE CONTACT, SKIN CONTACT AND
INGESTION.
1. Press Setup (F6).
2. Press Setup ProFlow (F4).
3. Press Change ProFlow (F1). The message Replace ProFlow Cover then
Close Cover and Press Continue is displayed.
4. Open the front printhead cover.
5. Fit the cover to the underside of the ProFlow transfer head unit.
Run Head
Paste
Load
Clean
Screen
Adjust Setup Monitor Maint.
Mode
Load
Data
Edit
Data
Setup
ProFlow
Change
Screen
Change
Tooling
Change
Language
Exit
Change
ProFlow
Load
Cassette
Prime
ProFlow
Exit
INFINITY
&21680$%/(5(3/(1,6+0(176
352)/2:
Software Version 7 User Manual 9.49
6. Release the latch on the front of the pressure mechanism and raise the
mechanism forwards and upwards to engage the spring locking device.
7. Open the locking clip securing the transfer head to the pressure mechanism
and carefully slide the transfer head out and away from the pressure mecha-
nism.
8. Invert the ProFlow transfer head and place onto the maintenance stand
(provided with the equipment).
9. Remove the cover from the ProFlow transfer head unit.