Screen XR Error This error reports that the X rear screen actuator failed to initialize to its
central datum.
Screen Y Error This error reports that the Y screen actuator failed to initialize to its central
datum.
Set Pressure %2.21f Actual Pressure %2.21f
(Front/Rear Squeegee)
This error reports if the front/rear squeegee pressure differs from the
pressure set by more than ± 1.00Kg.
Stop After Idle Time Exceeded This error reports if the idle time is exceeded, the options to continue or
abort are displayed. Continue resets the idle timer or abort allows for
Manual or Auto unload.
System Power Down This error reports that the 24V motor power has been switched off either
by the Emergency Stop button being activated (including upline and
downline external machines) or that the removable frame access cover has
been removed.
System Suspended While Covers Open This error reports that whilst the machine was switched on, one or more
of the cover interlock switches were out of position.
Table Movement Inhibited,
Camera Not Home.
This error reports that the camera is over the table and the NextMove is
sent an instruction to move the rising table.
This Diagnostic Cannot Run
Until Proflow Is At home
This error reports if proflow is not in the home position (Print Carriage
Diagnostics only).
This Diagnostic Cannot Run With Proflow
Fitted
This error reports if in Print Carriage Diagnostics, Move Print Carriage to
Paste Position is selected.
Unable to Find Fiducial This error reports that the vision system is unable to locate the relevant
screen or board fiducial.
Upline Board Transfer Error This indicates that there is a problem in loading a board from the upline
machine.
Upline Machine Not Available This error reports that the upline machine is unavailable to accept the next
board.
Window Error This error reports that the menu structure has failed to open correctly.
X Actuator Limit Exceeded This error reports that either X actuators are driven past its limit set during
calibration.
Y Actuator Limit Exceeded This error reports that the Y actuator is driven past its limit set during
calibration.
Error Message Interpretation
INFINITY
(55250(66$*(6
(55250(66$*(/,67,1*
4.8 User Manual Software Version 7
INFINITY
',$*1267,&6
,1752'8&7,21
Software Version 7 User Manual 5.1
CHAPTER 5 DIAGNOSTICS
INTRODUCTION The diagnostic function is an aid to the user to allow individual access and
control of motors and modules. It allows the user to control the sequence of the
machine so that a particular module can be exercised.
To enter the diagnostic mode press the Maint button.
The menu bar changes displaying the Diagnostic option.
Press the Diagnost (F6) button. If a password exists a window displays the
message Diagnostic Password’. If the password is incorrect control displays
the messageInvalid password entered’ and returns to the previous menu. If
the correct password is entered or no password exists a pop up window displays
the following:
The menu bar changes displaying the following:
Next / Previous keys move the highlight bar up and down the list of diagnostic
modules.
Select Module key opens a new window displaying the diagnostic functions
available for the selected module.
Exit returns operation to the start of initialization.
NOTE
Before any diagnostic function is used in any of the modules they must be homed
first or they are not able to initiate a command.
Run Head
Paste
Load
Clean
Screen
Adjust Setup Monitor Maint.
Calibrat
Pressure
Calibrat
Offset
Calibrat
Vision
House
Keeping
Set
Prefs
Diagnost
Tes t
Cycles
Exit
Module Diagnostic Page
System
Print Head
Print Carriage
ProFlow / Squeegee
Camera Axes
Rail System
Paste Dispense System
Screen Alignment
Screen Change
Screen Cleaner
Rising Table
MIU
Autoflex Tooling
Select
Module