INFINITY
',$*1267,&6
35,17&$55,$*(
Software Version 7 User Manual 5.11
Drive Carriage to
Front Position
Selecting this diagnostic function moves the print carriage to the front start
position of the print stroke. ‘Driving Print Carriage to Front Limit’ is
displayed in the prompt box.
Drive Carriage to
Paste Position
Selecting this diagnostic function moves the print carriage to a position that
clears the paste dispense unit if operated. ‘Driving Print Carriage to Paste
Position’ is displayed in the prompt box.
Drive Carriage to
Rear Position
Selecting this diagnostic function moves the print carriage to the end of the print
stroke. ‘Driving Print Carriage to Rear Limit’ is displayed in the prompt box.
Drive Carriage
Using Jog Buttons
Selecting this diagnostic function allows the user to position the print carriage
anywhere between the front and rear position using the two jog buttons. ‘Use
the Left Jog Button to move Print Carriage towards front and the Right Jog
Button to move it towards the rear’ is displayed in the prompt box.
Cycle Print
Carriage
Selecting this diagnostic function starts a continuous cycle of driving the print
carriage between its front and rear limits, pausing at each end for 2 seconds.
‘Print Carriage Cycling’ is displayed in the prompt box. The cycle is termi-
nated if the Stop key is used or the set cycle count is reached.
Cycle Count This diagnostic function displays the amount of cycles done and the amount of
cycles to go to complete the cycle count.

INFINITY
',$*1267,&6
352)/2:
5.12 User Manual Software Version 7
PROFLOW Selecting this diagnostics module opens the following window:
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of selectable
diagnostic functions.
Run Diagnost activates the diagnostic function, as selected by the highlight bar.
Exit returns operation to the module diagnostics page.
Adjust opens the following window:
NOTE
Idle Pressure is only available while a software controlled air regulator is fitted.
The menu bar changes to the following:
Next / Previous keys move the highlight bar up and down the list of diagnostic
parameters.
Incr. / Decr. keys change the value of the selected diagnostic parameter.
Exit returns operation to the ProFlow diagnostics page.
ProFlow Diagnostics
System Pressure
ProFlow Fitted
Paste Cassette Low
Software Pressure Regulator Fitted
11.42Kg
ON
OFF
Home ProFlow
Drive System to Contact Height
Drive System to Print Height
Home Downstop
Drive Downstop to Position
Drive System Using Jog Buttons
Drive Downstop Using Jog Buttons
Toggle Paste Pressure
ON
OFF
Run
Diagnost
Adjust Next Previous Exit
ProFlow Adjust Parameters
PFLOW CONTACT POS.
DOWNSTOP POS.
IDLE PRESSUE
0.0
0.0
0.2
mm
mm
bar
Next Previous Incr. Decr. Exit

INFINITY
',$*1267,&6
352)/2:
Software Version 7 User Manual 5.13
Home ProFlow Selecting this diagnostic function drives the ProFlow unit up to the home
position. If the downstop is in the way a warning is displayed.
Drive System to
Contact Height
Selecting this diagnostic function drives the ProFlow unit onto the screen, (a
slight pressure seal, is made between the ProFlow transfer head and the screen).
There is no pressure applied to the paste cassette.
Drive System to
Print Height
Selecting this diagnostic function drives the ProFlow transfer head down to
printing pressure (as setup in the Edit Data board file). There is no pressure
applied to the paste cassette at this time.
Home Downstop Selecting this diagnostic function drives the downstop to its home position (fully
raised).
Drive Downstop to
Position
Selecting this diagnostic function drives the downstop to the preset downstop
position (offset can be adjusted in the status menu page by selecting Maint. and
selecting Set Prefs menu).
Drive System
Using Jog Buttons
Selecting this diagnostic function enables the ProFlow unit to be moved up or
down by means of the jog buttons.
Drive Downstop
Using Jog Buttons
Selecting this diagnostic function enables the downstop to be moved up or down
by means of the jog buttons.
Toggle Paste
Pressure
Selecting this diagnostic function initiates pressure onto the paste cassette.
Before initiating pressure to the paste cassette, the transfer head must be in
contact with, and have an adequate seal with the screen. A warning is displayed
if toggle paste pressure is selected with the transfer head off the screen.
System Pressure This diagnostic function continuously displays the current pressure in kg,
exerted from the squeegee pressure load cell onto the ProFlow unit.
ProFlow Fitted Indication of electrical connection of ProFlow to the machine software.
Paste Cassette Low ProFlow paste low sensor activated (on), indicating paste low or empty or,
deactivated (off).
Software Pressure
Regulator Fitted
Switched to OFF indicates that the ProFlow unit is fitted with a mechanical
pressure regulator control. Switched to ON indicates that the software address-
able regulator control is activated, ie ProFlow not fitted with mechanical pres-
sure regulator.