DEK INFINITY USER MANUAL.pdf.pdf - 第261页

INFINITY ',163(& 7,21 ',163(&7,2 16(7 83 Soft ware Ver sion 7 User Manual 8.21 Edit Limit Se t 1. Select Edit Limits . NOTE Some buttons in the menu bar above may not be shown, depending if sites a…

100%1 / 356
INFINIT
Y
',163(&7,21
',163(&7,216(783
8.20 User Manual Software Version 7
3. Select Limit Options.
These are usually set to enabled. If for any reason a particular inspection
option is not required, set to disabled. If any global limit options are disabled
the corresponding limit sets and parameters are greyed out. These are global
limits, therefore they are active for the whole product. If a particular
inspection is not required for a specific type of site, this can be achieved later
in limit set options for the site.
4. Enter global limit options using Next, Previous, Incr. and Decr. keys.
5. Select Exit.
6. Select Exit.
Limit
Options
Next Previous Incr. Decr. Exit
Global Limit Set Options
Blockage
Smear
Paste
Alignment
Bridging
Volume
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
Next Previous Incr. Decr. Exit
Next Previous Incr. Decr. Exit
Limit
Options
Next Previous Incr. Decr. Exit
INFINITY
',163(&7,21
',163(&7,216(783
Software Version 7 User Manual 8.21
Edit Limit Set 1. Select Edit Limits.
NOTE
Some buttons in the menu bar above may not be shown, depending if sites
already exist.
The following window is displayed:
Limit sets list the different sets of limit parameters that are available, initially
only default is available. Limit parameters list the current limits for the
highlighted limit set.
2. At this point either:
a. Add limits to create a new limit set, continue with Add Limits below.
or
b. Edit limits to edit an existing limit set, go to the Edit Limits section.
NOTE
It is recommended that during setup, parameters are set at a level that no
alarms occur (coarse). Once the inspection is correctly setup, the parame-
ters can be tightened during production in adjust inspect.
Add Limits 1. Select Add Limits.
NOTE
Next limit and previous limit are only available if at least one limit, plus the
default, exist already.
Edit
Global
Edit
Limits
Delete
Site
Next
Site
Previous
Site
Edit
Site
Inspect
Site
Exit
Default
Default
10%
15%
0.01 sq mm
0.15 sq mm
90%
80%
0.02mm
0.03mm
0.05mm
0.04mm
80%
70%
LimitSetID
BlockageWarning
BlockageAlarm
SmearWarning
SmearAlarm
PasteWarning
PasteAlarm
AlignWarning
AlignAlarm
BridgeWarning
BridgeAlarm
VolumeWarning
VolumeAlarm
LimitSets
LimitParameters
Add
Limits
Edit
Limits
Next
Limit
Previous
Limit
Exit
INFINIT
Y
',163(&7,21
',163(&7,216(783
8.22 User Manual Software Version 7
2. Use the keyboard to enter the ID of the new limit set and press Enter.
NOTE
Limit ID may be any name up to 20 characters in length including spaces.
3. Enter parameters using the Next, Previous, Incr. and Decr. keys. A coarse
set of values is shown above.
4. Select Save Limits. The message Saving Fiducial Data - Please Wait
Board data file saved is displayed.
5. Select Exit.
6. Select Edit Limits.
7. Go to Step 3 of Edit Limits (next page).
EditLimitParameters
LimitSetID
BlockageWarning
BlockageAlarm
SmearWarning
SmearAlarm
PasteWarning
PasteAlarm
AlignWarning
AlignAlarm
BridgeWarning
BridgeAlarm
VolumeWarning
VolumeAlarm
COARSE
20
25
1.00 sq mm
1.50 sq mm
70
65
0.200mm
0.250mm
0.015mm
0.010mm
80
70
Save
Limits
Next Previous Incr. Decr. Exit
Save
Limits
Next Previous Incr. Decr. Exit
Save
Limits
Next Previous Incr. Decr. Exit
Add
Limits
Edit
Limits
Next
Limit
Previous
Limit
Exit