2OM-1751-003w_G5S.pdf - 第104页
2OM-1751 1-52 1303-001 4.2 "Opr .Mode" T ab Sheet [14] Poclet recog condition when restarting The conditions for pocket recognition when the machine operation is re- stared, are setup in this section. Function …

2OM-1751
1-51
[8] Tape Joint Detection
One of the following buttons can be selected to determine whether or not
an automatic teaching operation should be performed on the feeder pocket
recognition after a tape joint line has been detected.
Disable
Select this button not to perform an automatic teaching operation on the
feeder pocket recognition after a tape joint line has been detected.
Enable
Select this button to perform an automatic teaching operation on the feeder
pocket recognition after a tape joint line has been detected.
[9] Recog Interval at Joint
When the operation is re-started, the interval time is set up in this data box in
the case that the feeder pocket recognition automatic teaching is performed
periodically, based on the tape feeding times.
[10] Pocket Recog Start Pos
The pocket recognition starting position is setup in this data box.
[11] Pocket Recog End Pos
The pocket recognition ending position is setup in this data box.
[12] Joint recog judge by comp recog
"Enable" or "Disable" is selected for the spliced tape joint detection function
in this selection box.
Disable
It is selected when the joint detection is not used.
Enable
It is selected when the joint detection is to be used.
[13] Joint tolerance
The joint allowance is setup in this data box, in the case of using the "Joint
Recognition Judgment" function.
1303-001
4.2 "Opr.Mode" Tab Sheet

2OM-1751
1-521303-001
4.2 "Opr.Mode" Tab Sheet
[14] Poclet recog condition when restarting
The conditions for pocket recognition when the machine operation is re-
stared, are setup in this section.
Function Setting
"Enable" or "Disable" is selected for the pocket recognition condition in the
re-start operation, in this selection box.
Start condition
The time period from the machine stop (standby, stop or pause) mode to
machine operation start mode, is setup in this data box.
Recog Interval at Joint
The intervals for the automatic teaching to be performed periodically for the
feeder pocket recognition based on the number of tape feeding times when
the machine operation is re-started, are setup in this data box.
End condition (Interval)
The number of tape feeding times until the pocket recognition end, is setup
in this data box.

2OM-1751
1-531303-001
4.2.8 Splicing
When the [Splicing] button is pressed on the "Opr.Mode" tab sheet, the following
window appears.
[3]
[2]
[1]
[4]
F2A35
[1] Splicing tape length
The splicing tape length is set in this text box.
[2] "Stop Mode" Group Box
Splicing Stop (900 mm)
The [Enable] or the [Disable] button can be selected to determine whether or
not the machine should be stopped for tape splicing required when the length
of the remaining tape becomes shorter than 900 mm.
[3] "Warning Mode " Group Box
The following conditions can be added to the criterion (Length of Remaining
Tape: 900 mm) to set the time to issue a warning of splicing need.
Note
It cannot be specied to issue a splicing warning message with the length
of the remaining tape shorter than 900 mm.
900 mm + Condition
The condition for displaying the alarm for splicing, is selected from the
following items.
4.2 "Opr.Mode" Tab Sheet