2OM-1751-003w_G5S.pdf - 第180页

2OM-1751 2-58 1303-001 3.7 Placement (G02_02) Offset Offset X [mm] and Of fset Y [mm] Set the offset values for all placement coordinate X and Y in the placement data (P-data) and the image and local PEC recognition coor…

100%1 / 380
2OM-1751
2-57
(G02) Offset
When the [Offset] button is pressed in the "Placement" window, the
following tab sheet appears.
F2B46
(G02_01)
Unit Control
Select one of the following options to determine whether the selected
placement data should be used.
In normal cases, select "Placement".
Placement
: The placement data of the selected unit (group) becomes valid.
Bypass
: The placement data of the selected unit (group) becomes
invalid.
1303-001
3.7 Placement
Graphic
Development
2OM-1751
2-581303-001
3.7 Placement
(G02_02)
Offset
Offset X [mm] and Offset Y [mm]
Set the offset values for all placement coordinate X and Y in the placement
data (P-data) and the image and local PEC recognition coordinates.
Note
(a) Use "+00.00" (zero) in normal cases.
(b) Note that these offsets are not reected on "X [mm]" and "Y [mm]" in
"A02_04 Fiducial mark".
Offset Z [deg]
Set the offset value for all placement angles (Z=Theta) in the placement data
(P-data).
Note
Use "0.00" in normal cases.
Offset H [mm]
Set the offset value for all placement height "H" in the placement data
(P-data).
Note
In normal cases, set "+0.000" in this text box.
(G02_03)
Unit PCB Fiducial
Select one of the following options to determine whether or not the unit PCB
BBR function should be used.
Disable
: The unit PCB BBR function is not used.
Enable
: The unit PCB BBR function (2-point recognition) is used.
Y
1
X
2
Y
2
X
1
Second Fiducial Mark
Pattern Origin
First Fiducial Mark
Placement Coordinate
Reference
F2B47
2OM-1751
2-59
(G02_04)
Recog Coord X1 [mm] and Recog Coord Y1 [mm]
Set the X1 and Y1 coordinates of the rst ducial mark based on the pattern
origin.
Recog Coord X2 [mm] and Recog Coord Y2 [mm]
Set the X2 and Y2 coordinates of the second ducial mark based on the
pattern origin.
(G02_05)
Fiducial Mark FM1 and Fiducial Mark FM2
Set the mark Nos. of the rst and second ducial marks FM1 and FM2.
Select the mark Nos. (Mark Codes) specied in the PEC recognition mark
data of the operation data.
(G02_06)
Unit PCB Recognition
One to three points are setup for the PEC recognition for each U data.
U02U01
Global Recognition
Unit PCB Recognition
F2A48
1303-001
3.7 Placement