2OM-1751 6-31 1303-001 7.1.1 Fdr Pick-up T ch Procedure (1) Press the head selection button. (2) Press the [Block Sel] button. (Select the appropriate block and select the tape feeder where the teaching is performed). (3…

100%1 / 380
2OM-1751
6-301303-001
7.1 "Fdr Pick-up Tch" Window
In this window, the teaching is performed with the manual alignment operation
using the PEC recognition camera, for the offset data items to absorb the
dispersion caused by each feeder’s difference in characteristics, out of the offset
data items related to the feeder’s component pick-up operation on the feeder base.
[1]
[4]
[3]
[2]
F2F33
[1] [Head Sel] Button
The buttons showing each head are displayed as images.
Using these buttons, the head (PEC recognition camera) to be used in the
teaching is selected.
[2] [Block Sel] Button
The buttons showing each feeder base are displayed as images.
Using these buttons, the block where the teaching is performed, is selected.
[3] Tape Feeder Select Button
Using this button, the tape feeder where the teaching is performed is selected
in the selected block.
[4] [Activate] Button
When pressed, the "Manual Alignment" window appears for the selected
tape feeder No.
Graphic
Development
7.1 "Fdr Pick-up Tch" Window
2OM-1751
6-311303-001
7.1.1 Fdr Pick-up Tch
Procedure
(1) Press the head selection button.
(2) Press the [Block Sel] button.
(Select the appropriate block and select the tape feeder where the teaching is
performed).
(3) Press the [Activate] button.
(The window is changed to the manual alignment window for the selected
tape feeder.)
F2F34
(4) Press the [Send Comp] button.
(Find the place necessary on the tape).
(5)
When the manual alignment is not required :
Press the [Prev Fdr.] or [Next Fdr.] button to perform the manual alignment
for the other tape feeder.
When the manual alignment is required :
Follow the steps (5) and later.
7.1 "Fdr Pick-up Tch" Window
2OM-1751
6-321303-001
(6) Press the [Eye Match] button.
(Start the manual alignment operation from the position shown using an
arrow).
F2F35
(7) Press the [ ] button if necessary.
(Check the nozzle pick-up position).
F2F36
(8) When the manual alignment operation is completed, press the [OK] button.
(In the case that the performed manual alignment is cancelled, press the
[Cancel] button.)
(9) Press the [Save] button to save the manual alignment results.
7.1 "Fdr Pick-up Tch" Window