2OM-1751 1-57 1303-001 4.2.10 Noz Blow This function is used to prevent the nozzle clogging. Using this function can extend the nozzle maintenance interval. When the [Noz Blow] button is pressed on the "Opr. Mode&qu…

100%1 / 380
2OM-1751
1-561303-001
Continuation 2
The system keeps on saving the data when the component data has the same
ID and is not used.
(Continuation 2)
(Before Changeover)
101 AAA
102 BBB
103 CCC
104 DDD
(After Changeover)
The 102 data is initialized because
there is a difference.
The 104 data is sustained because
it is not used.
The other data is continued.
101 AAA
102 DDD
103 CCC
104
Continued
Initialized
Continued
Continued
Edited Data
F2A39
[2] Temp Comp Lib Edit Mode
The changing method for the edited data is selected in this text box.
Standard
The edited data is maintained.
Comp Lib Priority
When selected, this button initializes the pieces of data having the changed
IDs to be those in the component library data.
4.2 "Opr.Mode" Tab Sheet
2OM-1751
1-571303-001
4.2.10 Noz Blow
This function is used to prevent the nozzle clogging.
Using this function can extend the nozzle maintenance interval.
When the [Noz Blow] button is pressed on the "Opr. Mode" tab sheet, the
following window appears.
[2]
[1]
[4]
[3]
[5]
F2A40
[1] Head 1, Head 2
Disable
When this button is selected, the nozzle air blowing function is not activated.
Enable
When this button is selected, the nozzle air blowing function is activated.
[2] Effective only under "WAIT"
Disable
The nozzle air blowing function is used during the Machine (STANDBY)
mode.
Enable
The nozzle air blowing function is used based on the set timing.
Graphic
Development
4.2 "Opr.Mode" Tab Sheet
2OM-1751
1-581303-001
[3] Execution Timing
Specify the timing to execute the air blowing.
Operation time
Select this button to specify the timing of the execution based on the running
time.
PCB Count
Select this button to specify the timing of the execution based on the number
of PCBs.
[4] Count
The set value is designated based on the item selected in executive timing.
When the [Run Time] is selected, the interval from the automatic operation
start to the air blow execution is set based on time.
When the [PCB Counter] is selected, the interval from the automatic
operation start to the air blow execution is set based on the completed
number of PCBs.
[5] [Blow Count] Button
Specify the number of blowing times.
4.2 "Opr.Mode" Tab Sheet