2OM-1751-003w_G5S.pdf - 第162页

2OM-1751 2-40 1303-001 (D02) PCB locate Data When the [PCB locate] tab is pressed in the "Control" window, the following tab sheet appears. F2B37 In PCB Vacuum Support F2B38 Graphic Development 3.4 Control

100%1 / 380
2OM-1751
2-391303-001
PCB Bottom [mm]
When PCBs with some components already mounted on the lower surfaces
(back) by the input machine are transferred to this machine, be sure to enter
the thickness of the highest component in the text box.
Tallest Previously Placed Component
PCB
Set this thickness in the text box.
F2B36
Data Input Range
0 to 30.000
Note
(a) The set parameter is used to determine the position (elevation) of the
rst backup table when the PCB is transferred to the PCB positioning
section.
(b) When components are placed previously and the main machine is
operated with "0.00" (no previously placed components) in this text
box, the support pins may interfere with some of the previously
placed components on the back of PCB while the PCB is being
transferred to the PCB positioning section.
(D01_04)
PEC expansion correction
"Enable" or "Disable" for the PEC Recognition Extension Correction, is
selected in this selection box.
3.4 Control
2OM-1751
2-401303-001
(D02) PCB locate Data
When the [PCB locate] tab is pressed in the "Control" window, the following
tab sheet appears.
F2B37
In PCB Vacuum Support F2B38
Graphic
Development
3.4 Control
2OM-1751
2-411303-001
(D02_01)
PCB detection off DLY
The time period from the PEC recognition to PCB release is set in this text
box.
(D02_02)
PCB locate SET
Common :
When selected, the PCB positioning is set commonly to the
machines in the line.
Individual :
When selected, the PCB positioning is set individually for each
machine in the line.
(D02_03)
PCB locate Sequence
The PCB positioning mode is set in this text box.
Backup Base + Z Clamp
: When selected, the positioning is performed
using the backup base and the Z-clamp.
Z Clamp
: When selected, the positioning is performed
only using the Z-clamp.
PCB vacuum support
: When selected, the positioning is performed
using the vacuum jig.
(D02_04)
UP
Positioning 1, Positioning 2
MOVE
The PCB moving up operation for positioning is selected from "Standard" or
"Value Set".
Normally, "Standard" is selected.
Standard
:
When selected, the PCB is moved up for positioning
based on the standard value set in the machine.
Low Speed 1
:
When selected, the operation speed is one step lower
than the standard value.
Low Speed 2
:
When selected, the operation speed is two step lower
than the standard value.
Low Speed 3
:
When selected, the operation speed is three step lower
than the standard value.
Low Speed 4
:
When selected, the operation speed is four step lower
than the standard value.
Value Set
: When selected, the speed value can be set freely.
3.4 Control