2OM-1751 1-17 1303-001 3.1 Cmp.Rem.List The list of the remaining components in the production line, can be checked in this window. When the [Line] button is pressed in the "Comp Reload" window, the following w…

2OM-1751
1-161303-001
[12] Alternate
In this section, "Enable" or "Disable" is set for the "Alternate" function in the
feeder where the feeder "Alternate" function has been setup.
Source Feeder
to be Alternated
Alternated Feeder
F2A13
: Feeder where the feeder "Alternate" function has been setup
: Feeder where the components are being picked up
: Feeder where the feeder "Alternate" function has been
disabled
3. "Comp.Reload" Window

2OM-1751
1-171303-001
3.1 Cmp.Rem.List
The list of the remaining components in the production line, can be checked in
this window.
When the [Line] button is pressed in the "Comp Reload" window, the following
window appears.
[1]
[2]
F2A14
[1] Feeder List
The feeder status in the selected machine is displayed in this area.
Reference
Refer to "3. "Comp Reload" Window" in Chapter 1 for the feeder list
details.
[2] Machine List
The list and status of the machines set in the line conguration are displayed
in colors.
When the machine in which the feeder is to be checked, is selected, the
feeder list of the selected machine is displayed in the feeder list area.
3.1 Cmp.Rem.List
Graphic
Development

2OM-1751
1-181303-001
4. "OPERATION" Window
The constraints based on the designation of any of the various operation modes in
the automatic operation and operation method in the test operation, are set in this
window.
[1]
F2A15
[1] Tabs and Tab Sheets
The "OPERATION" window is provided with the following four tabs. When
each tab is pressed, the corresponding tab sheet appears inside the window.
Tabs Description
Run Mode
The corresponding tab sheet enables the operator to change the
operation mode or stop the production.
Opr. Mode
The corresponding window enables the operator to select an operation
mode such as Over Tact-Time Reduction.
Test Mode
The corresponding window enables the operator to set test modes.
Altn Mode
The corresponding tab sheet enables the operator to set the "Feeder
Alternate"function.
T2A1
Graphic
Development
4. "OPERATION" Window