2OM-1751-003w_G5S.pdf - 第377页

2OM-1751 6-105 1303-001 8. "PCB.CNT ." Window This window enables the operator to set the number of PCBs to be produced. [2] [1] F2F122 [1] PCB Counter Stop Mode PCB Counter Stop Mode [Designate] Button : When …

100%1 / 380
2OM-1751
6-104
Teaching Procedure
Procedure
(1) Press the [Fdr Select] button to select the feeder for which the teaching
operation is performed.
(2) Press the [Move Adjust] button.
(The recognition window will be displayed to enable the manual alignment
operation).
F2F121
Note
In the case that the subject for which the manual alignment operation is
not within the camera view, press the button on the recognition window to
return the "Eye Match Guide" window and move the beam.
(3) Move the eccentric pick-up position of the subject for which the manual
alignment operation is performed, so that it is the center of the cross hairs
using the image movement button in the recognition window.
(4) Press the [OK] button to determine the position.
(The teaching results are displayed in the data boxes for the pick-up position
corrected values.)
(5) Press the [Save] button.
(The conrmation window for the data saving will be displayed).
When [Yes] is pressed, the data is reected on the component library data
and saved.
When [No] is pressed, the data saving operation is stopped.
1303-001
7.5 "PU Pos Ofst Tch" Window
2OM-1751
6-1051303-001
8. "PCB.CNT." Window
This window enables the operator to set the number of PCBs to be produced.
[2]
[1]
F2F122
[1] PCB Counter Stop Mode
PCB Counter Stop Mode
[Designate] Button
: When this button is selected and the
produced PCBs reach the value set in
"Count" text box, the PCB intake is
stopped and after all the PCBs in the
machine are discharged, the machine is
automatically stopped.
[No Designate] Button
: When this button is selected, the PCB
counter stop mode is not used.
Count
The number of produced PCBs for each lane for stopping the machine using
the PCB Counter Stop Mode, is set in this group box.
Note
The set count is displayed in the "Count" data box in the "AUTO. OPN"
window.
[2] [Init Value] Button
When this button is pressed, the set value for the "PCB Counter Stop Mode"
is returned to the initial value.
Graphic
Development
8. "PCB.CNT." Window
2OM-1751
6-1061303-001
PCB Counter Stop Procedure
Procedure
(1) Display the "PCB.CNT." window.
(2) Set the "PCB Counter Stop Mode" to "Designate".
(3) Press the [Count] button to display the "Count" window and read the "Count"
barcode in the instruction sheet using the barcode reader attached to the
machine. (The value read using the barcode reader, will be displayed in the
"Count" window).
"Count" window F2F123
(4) Conrm the read value and when it is OK, press the [Set] button.
(5) Conrm that the read value has been entered in the "Count" data box.
Note
When the value in the "Count" data box is re-set, press the [Count] button and
change the set value.
8. "PCB.CNT." Window