CP45FVNEO Maintenance Reference (Eng, Ver3).pdf - 第101页
Lubricant Method 4-13 Inject adequate volume of grease through LM guide grease nipples (A) and (B) at the entry and exit of the conveyor using th e grease injection device provided by us. Upon completion of injection…

Samsung Component Placer CP45NEO Series Maintenance Guide
Questioning dialog box appears. Click the yes (Y) button.
Using the teaching box, move the X-axis to the adequate position for grease injection
on the lead screw of the conveyor and the LM guide.
Warning
After clicking the “Motor Free” button on the teaching box,
click the “Stop” button on the front operation panel.
Conduct inspection while the motor power supply is turned
off.
Remove dust and foreign matter from the LM guide rail and LM screw using the
clean cloth in the clean kit supplied by us.
Apply grease thinly on the lead screws of the entry and exit using a paint brush.
4-12

Lubricant Method
4-13
Inject adequate volume of grease through LM guide grease nipples (A) and (B) at the
entry and exit of the conveyor using the grease injection device provided by us.
Upon completion of injection, reciprocate from the minimum width (30mm) to the
maximum width (400mm) of the conveyor 3 to 4 times in order to uniformly spread
the grease on the lead screw and LM guide rail. [Minimum width (90mm) to
maximum width (460mm) of large PCB type]

Samsung Component Placer CP45NEO Series Maintenance Guide
4.2.3.2. Chain for Adjusting Conveyor Width On Manual Operation
Inspection
Check for contamination on the chain.
Insufficient lubricant on the chain could cause difficulties in adjusting the conveyor
width. Check the condition of the lubrication.
Figure 4-5. Chain for Adjusting Conveyor Width On Manual Operation
Solution
Repeat 2 to 3
times.
Chain
Belt
Using the teaching box, move the X-axis to the adequate position for grease injection
on the chain for manual width adjustment.
4-14