CP45FVNEO Maintenance Reference (Eng, Ver3).pdf - 第87页

W eekly Inspection 3-37  If abnormal noise and operational problem still occur, turn of f the main switch of the machine again and replace the cooling fan  Assembling is done in the reverse order . Wa r n i n g The coo…

100%1 / 139
Samsung Component Placer CP45NEO Series Maintenance Reference
Main switch turn-of
f
direction (clockwise)
Warning
When the main switch is turned on, since the cooling fan
operates, user’s hand may get injured. Careless touching
of the cable, etc. may cause electric shock. Therefore,
special care is need while performing work.
Check the operation state of the two cooling fans in the control rack and if the noise
of the cooling fan is acceptable and there is no problem in its operation, clean the dust
in the control rack using vacuum cleaner and assemble it in the reverse order of
disassembling.
3-36
Weekly Inspection
3-37
If abnormal noise and operational problem still occur, turn off the main switch of the
machine again and replace the cooling fan
Assembling is done in the reverse order.
Warning
The cooling fan replacement work accompanies a danger.
Therefore, contact our C/S company or local agent.
3.2.9. Lubrication and Grease Application
For details relating to the lubrication and grease application, refer to Chapter 4 .
Lubricant Method (page 4-1).
Caution
Since the lubrication and grease application for the
machine is critical to the lifetime of the machine, ensure
that periodical lubrication and grease application are
performed.