Daily Inspection
2-15
Scale for the lower pressure limi
t
Scale for the upper pressure limit
Decreasing
the pressure
Increasing
the pressure
If the pneumatic pressure does not change even after turning the regulator on the air
panel on the front side of the machine or if the pressure switch does not operate under
the state that the pressure is out of the set range (between the green scales), contact
our C/S company (STS) or local agent immediately for adjustment..
Caution
The incorrectly set pressure may cause problem in the
function and capability of the machine. Adjust the set
pressure correctly.

Weekly Inspection
Chapter 3 . Weekly Inspection
3-1
3.1. Weekly Inspection
3.1.1. Nozzle Holder
Inspection
As the nozzle holder may be bent by improper operation during the placement of parts,
possible bending of the nozzle holder should be checked frequently. Bending causes
serious errors such as rotation of Z-axis eccentricity and inaccurate placement to occur.
Figure 3-1. Nozzle Holder
Solution
Operate the teaching box to move the head assembly to the front side as far as
possible.