CP45FVNEO Maintenance Reference (Eng, Ver3).pdf - 第56页
Samsung Component Placer CP45NEO Series Maintenance Refer ence Main switch turn-of f direction ( counterclockwise) Block the main pressurized air at the ai r panel on the rear of the machine. Caution Shock caused by pr…

Weekly Inspection
3-5
Operate the teaching box to move the Head Assembly to the front side as far as
possible so that front and rear head assemblies do not interfere with each other.
Warning
After clicking the “Motor Free” button on the teaching box,
click the “Stop” and “Reset” buttons on the front operation
panel. Conduct inspection while the motor power supply is
turned off.
If the working space is insufficient, move the head assembly manually to the front
side
After terminating the MMI and computer, Turn off the main switch on the front
side of the machine.

Samsung Component Placer CP45NEO Series Maintenance Reference
Main switch turn-of
f
direction
(
counterclockwise)
Block the main pressurized air at the air panel on the rear of the machine.
Caution
Shock caused by pressurization while blocking the
pressurized air may be caused. Please handle with care.
Remove the top cover of the head assembly with a “+” shaped screwdriver.
After removing the pressure gauge on the head assembly air module by turning the
10mm spanner counterclockwise, assemble the elbow fitting by turning the 10mm
3-6

Weekly Inspection
3-7
spanner clockwise, and supply air pressure through the connection hose.
Lay a clean cloth at the bottom of the nozzle holder of head 01 and blow out
repeatedly by pressing the manual switch of So1 ten times.
Blow out head 02 to head 06 in the same way.
According to the state of the impurities collected on the cloth, remove the vacuum
filter and clean or replace it every two months.