W eekly Inspection 3-21 Solution Head Air Module Pressure Gage Coil T ube Linking part of Coil T ube Operate the teaching box to move the head assembly to the front side as far as possible and click the motor free butt…

Samsung Component Placer CP45NEO Series Maintenance Reference
Caution
Washing the cooling fan filter with water may cause damage
to the filter by making it harden. Be sure that clean in th
determined methord.
In case the cover cooling fan does not operate, please contact our customer
satisfaction company (STS) or local agent.
3.1.9. Electric Device
Inspection
Check abrasive wear in each area of the device.
Check if the machine generates errors when the switch is operated.
Check if the corresponding input and output of the MMI IO window runs properly.
(Emergency Switch, Door Switch)
Check if the power is turned off in the machine when the main power switch is turned
off.
Solution
Contact our local agent for service when severe abrasive wear is present or the
machine does not work properly.
Warning
Before checking abrasive wear, be sure to turn off power,
lock, and check.
3.2. Monthly Inspection
3.2.1. Head Section
Check the state of contamination and operation over all of the head parts.
3.2.1.1. Coil Tube
Inspection
Check if there is any twist or abnormal air leakage by wear in the coil tube connecting the
head assembly and air module.
3-20

Weekly Inspection
3-21
Solution
Head Air Module
Pressure Gage
Coil Tube
Linking part of Coil Tube
Operate the teaching box to move the head assembly to the front side as far as
possible and click the motor free button.

Samsung Component Placer CP45NEO Series Maintenance Reference
Warning
After clicking the “Motor Free” button on the teaching box,
click the “Stop” and “Reset” buttons on the front operation
panel. Conduct inspection while the motor power supply is
turned off.
Open the window and check if the pressure reading on the pressure gauge of the air
module at the head assembly is abnormal (less than 0.1Mpa).
Open the window and check visually if there is any twist in the coil tube. Straighten
any part that is twisted.
Check by hand whether there is any abnormal air leakage by the wear of the coil tube.
If there is any abnormal air leakage, replace with a new coil tube.
3.2.1.2. Blow Quantity Inspection
Inspection
In case the reading of pressure gauge on the head air module is below 0.1Mpa, there may
be problems in the placement of parts.
Solution
In case the volume of blow is abnormal, please adjust in contact with our C/S company
(STS) or local agent.
Head Air Module
Pressure Gage
3.2.1.3. Flying Vision
Inspection
If there is any contamination on the surface of the Flying Vision Lens and Flying Vision
Lightning, the vision might not recognize shapes properly. Check the Flying Vision Lens
and Flying Vision Lightning for any dust or contamination frequently.
3-22