Daily Inspection 2-15 Scale for the lower pressure limi t Scale for the upper pressure limi t Decreasing the pressure Increasing the pressure If the pneumatic pressure does not change even after turning the regulator o…

Samsung Component Placer CP45NEO Series Maintenance Reference
2.6. Setting up pneumatic pressure of the machine
Inspection
Check if the supplied pneumatic pressure is as high as the set pressure (0.45 ~ 0.55
MPa) by the air pressure gauge through air panel on the front side of the machine.
If the pneumatic pressure of the machine is lower than the normal pressure, the
switch operates automatically to check the occurrence of an error.
Figure 2-2.Checking the pneumatic pressure
Solution
Pressure Gauge
Regulator
Air Filter & Auto Draine
r
Pressure Gauge & Auto Switch
If the pneumatic pressure of the machine is higher than the upper limit of the pressure,
turn the regulator on the air panel on the front side of the machine counterclockwise
to maintain the normal pressure. Conversely, If the pneumatic pressure of the
machine is lower than the lower limit of the pressure, turn the regulator clockwise to
maintain the normal pressure.
2-14

Daily Inspection
2-15
Scale for the lower pressure limi
t
Scale for the upper pressure limit
Decreasing
the pressure
Increasing
the pressure
If the pneumatic pressure does not change even after turning the regulator on the air
panel on the front side of the machine or if the pressure switch does not operate under
the state that the pressure is out of the set range (between the green scales), contact
our C/S company (STS) or local agent immediately for adjustment..
Caution
The incorrectly set pressure may cause problem in the
function and capability of the machine. Adjust the set
pressure correctly.